Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • タンパク質解析
  • イムノアッセイ
  • Newest assay kits
  • pHSense Eu Fab Anti-Human IgG, 96 wells

pHSense Eu Fab Anti-Human IgG, 96 wells

Image generic pHSense
pHSense Eu Fab Anti-Human IgG, 96 wells
Image generic pHSense
Generic pHSense
Image generic pHSense
pHSense™ Eu Fab is a europium-labeled, pH-sensitive Fab reagent that enables real-time, no-wash detection of antibody internalization and intracellular trafficking in live-cell assays.
View product information
Feature Specification
Application Internalization
Sample Volume 50 µL
pHSense™ Eu Fab is a europium-labeled, pH-sensitive Fab reagent that enables real-time, no-wash detection of antibody internalization and intracellular trafficking in live-cell assays.
View product information
Product variants
Unit Size: 96 wells
Part #:
81HUEU1AA
Unit Size: 2 x 96 wells
Part #:
81HUEU1AB
Unit Size: 10 x 96 wells
Part #:
81HUEU1AC
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Request more information
Image generic pHSense
pHSense Eu Fab Anti-Human IgG, 96 wells
Image generic pHSense
Generic pHSense
pHSense Eu Fab Anti-Human IgG, 96 wells
Image generic pHSense
Quick links
  • Variants
  • Product information
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Recently viewed
  • Get help

Product information

  • Overview
  • How it works
  • Assay validation
  • Specifications

Overview

pHSense™ Eu Fab reagent is a covalently europium-labeled, pH-sensitive Fab fragment designed to monitor antibody or antibody-drug conjugate (ADC), as well as receptor- and membrane protein-mediated internalization in real time. It binds with high affinity to the Fc region of test antibodies, particularly mouse IgG2 subtypes, and remains minimally fluorescent at neutral extracellular pH (≥7). Upon internalization, the Fab-antibody complex encounters increasingly acidic intracellular compartments such as early and late endosomes and lysosomes, where the europium signal becomes progressively stronger. This novel pH sensitive europium complex is compatible with a time-resolved fluorescence (TRF) detection, effectively eliminating most fluorescence background and significantly enhancing the signal-to-background ratio. Its unique photophysical properties enable simple and robust no-wash detection of receptor-mediated endocytosis of antibodies in plate-based assays with live cells.

How it works

pHSense Eu Fab Anti-human IgG: Internalization assay principle

pHSense Eu Fab reagent is a covalently europium-labeled, pH-sensitive Fab fragment designed to monitor antibody or antibody-drug conjugate (ADC) as well as receptor- and membrane protein-mediated internalization in real time. It binds with high affinity to the Fc region of test antibodies, and remains minimally fluorescent at neutral extracellular pH (≥7). Upon internalization, the Fab-antibody complex encounters increasingly acidic intracellular compartments such as early and late endosomes and lysosomes, where the europium signal becomes progressively stronger.

Image generic R&D attributes assay principle pHSense Fab
pHSense generic graph

Assay protocol for monitoring antibody or ADC internalization

The assay begins by culturing cells in a 96-well plate. The test antibody or ADC is pre-incubated with pHSense Eu Fab at a 1:2 molar ratio in cell culture medium for 30 minutes at room temperature. The resulting complex is then added to the cells and then incubated at 37°C, followed by kinetic or endpoint fluorescence measurement using an HTRF-compatible plate reader.

Image generic R&D attributes assay protocol Fab internalizing

Assay protocol for monitoring receptor and membrane protein-mediated internalization

The assay begins by culturing cells in a 96-well plate. The antibody directed against the target of interest is pre-incubated with pHSense Eu Fab at a 1:2 molar ratio in cell culture medium for 30 minutes at room temperature. This mixture is then added to the cells and incubated for 1 hour at room temperature. Following this incubation, cells are stimulated with a pharmacological compound. Fluorescence is then measured either kinetically or at endpoint using an HTRF-compatible plate reader.

Image generic R&D attributes assay protocol Fab non-internalizing

Assay validation

pHSense-based monitoring of internalizing antibody and ADCs

BT-474 cells were seeded in a 96-well white culture-treated plate at a density of 20,000 cells per well in complete culture medium, and incubated overnight at 37°C with 5% CO₂. The anti-HER2 internalizing antibody IgG1 Trastuzumab and two derived ADCs (Trastuzumab-Emtansine and Trastuzumab-Deruxtecan) were pre-incubated at room temperature for 30 minutes with pHSense Eu Fab at a 1:2 molar ratio in cell-culture medium. The Fab–antibody mixtures were then serially diluted in cell-culture medium and 50 µL of each dilution was added to the cells, followed by 1H incubation at 37°C with 5% CO2.

The fluorescence signal was recorded using an HTRF-compatible plate reader.

A dose-dependent increase of the signal demonstrated that pHSense Eu Fab can specifically detect the internalization of both anti-HER2 antibody and its ADC derivatives. Results obtained with the 2 tested ADCs suggest that the assay is not affected by the nature of the payload or the linker used in ADC design. No signal increase was observed when an irrelevant human IgG1 was used as negative control.

assay validation Eu Fab anti-Human IgG activator Internalizing antibody ADC

pHSense-based monitoring of Dulaglutide internalization: a GLP-1 analog covalently linked to Fc Fragment of IgG4

Tag-Lite® GLP1R cells (stable cell line, Part #: C1SU1GLP1, Revvity) were seeded in a 96-well white, culture-treated plate at a density of 80,000 cells per well in complete culture medium and incubated overnight at 37°C with 5% CO₂. Dulaglutide, a GLP-1R agonist consisting of a GLP-1 analog covalently linked to the Fc fragment of human IgG4, was pre-incubated at room temperature for 30 minutes with pHSense Eu Fab at a 1:2 molar ratio in cell culture medium. The Fab–Dulaglutide mixture was then serially diluted in cell-culture medium and 50 µL of each dilution were added to the cells, followed by 20 min incubation at 37°C with 5% CO₂. The fluorescence signal was recorded using an HTRF-compatible plate reader. A dose-dependent increase in signal with Dulaglutide, and the absence of signal with an irrelevant human IgG4, demonstrated that pHSense Eu Fab can specifically monitor GLP1R internalization.

assay validation Eu Fab anti-Human IgG inhibitor Dulaglutide

Specifications

Application
Internalization
Brand
pHSense
Detection Modality
pH sensitive dye
Product Group
Fluorescent Reagent
Sample Volume
50 µL
Shipping Conditions
Shipped in Dry Ice
Target
Human IgG
Target Class
Cell surface proteins, antibodies, ADCs
Target Species
Human
Technology
TRF
Unit Size
96 wells

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Flyer:-:2
  • Technical Note:-:3
1-3 of 3 Resources
Technical Note Icon
Technical Note
pHSense Eu probes for time-resolved fluorescence-based monitoring of antibody and ADC internalization

Antibody internalization is a critical step for evaluating the efficacy of therapeutic antibodies and antibody-drug conjugates...

Learn more
Technical Note Icon
Technical Note
phsense eu probes time-resolved fluorescence plate based applications for monitoring internalization of overexpressed and endogenous GPCRs

This techincal note explores how pHSense™ Eu TRF probes enable no-wash, live-cell detection of GPCR internalization across...

Learn more
Technical Note Icon
Technical Note
pHSense™ setup recommendations for Revvity microplate readers
Learn more

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.