Skip to main content
Revvity logo
Contact us
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • ゲノム解析
  • ライブラリー調製キット
  • NEXTFLEX Rapid Directional RNA-Seq Kit 2.0

NEXTFLEX Rapid Directional RNA-Seq Kit 2.0

Robust library prep kit that generates high-complexity libraries for NGS on Illumina and Element platforms.
NEXTFLEX Rapid Directional RNA-Seq Kit 2.0
Robust library prep kit that generates high-complexity libraries for NGS on Illumina and Element platforms.
Robust library prep kit that generates high-complexity libraries for NGS on Illumina and Element platforms.

The NEXTFLEX™ Rapid Directional RNA-seq Kit 2.0 is a fast, strand-specific total RNA-seq library-prep solution that converts 10 ng – 5 µg total RNA or 5 ng – 1 µg rRNA-depleted RNA into high-quality libraries for Illumina® sequencers and Element Biosciences™ AVITI™ systems through a streamlined workflow. Its chemistry preserves strand orientation and enables sensitive detection of mRNA, circular RNA, polyadenylated or non-polyadenylated long non-coding RNA (lncRNA), antisense transcripts and any other low-abundance RNAs, essential for transcript-discovery and differential-expression studies.

When paired with NEXTFLEX Poly(A) Beads 2.0 or the NEXTFLEX RiboNaut™ rRNA Depletion Kit, the kit delivers high coverage uniformity, low sequence-duplication rates and minimal residual rRNA. Automation-ready for Revvity’s Sciclone™ G3 NGSx and Zephyr™ G3 workstations and available in 8, 48 or 96-reaction formats, the kit scales seamlessly from low-input exploratory projects to high-throughput and clinical-research pipelines.

View product information ビュー related reagents
Feature Specification
Automation Compatible Yes
Request a sample
ビュー related reagents

The NEXTFLEX™ Rapid Directional RNA-seq Kit 2.0 is a fast, strand-specific total RNA-seq library-prep solution that converts 10 ng – 5 µg total RNA or 5 ng – 1 µg rRNA-depleted RNA into high-quality libraries for Illumina® sequencers and Element Biosciences™ AVITI™ systems through a streamlined workflow. Its chemistry preserves strand orientation and enables sensitive detection of mRNA, circular RNA, polyadenylated or non-polyadenylated long non-coding RNA (lncRNA), antisense transcripts and any other low-abundance RNAs, essential for transcript-discovery and differential-expression studies.

When paired with NEXTFLEX Poly(A) Beads 2.0 or the NEXTFLEX RiboNaut™ rRNA Depletion Kit, the kit delivers high coverage uniformity, low sequence-duplication rates and minimal residual rRNA. Automation-ready for Revvity’s Sciclone™ G3 NGSx and Zephyr™ G3 workstations and available in 8, 48 or 96-reaction formats, the kit scales seamlessly from low-input exploratory projects to high-throughput and clinical-research pipelines.

View product information ビュー related reagents
Product variants
Compare all
Remove all
Add to compare Add to compare
削除
Unit Size: 8 rxns
フォーマット
手動式
Part #:
NOVA-5198-01
Add to compare Add to compare
削除
Unit Size: 48 rxns
フォーマット
手動式
Part #:
NOVA-5198-02
Add to compare Add to compare
削除
Unit Size: 96 rxns
フォーマット
手動式
Part #:
NOVA-5198-03
Add to compare Add to compare
削除
Unit Size: 96 rxns
フォーマット
自動化対応容量
Part #:
NOVA-5198-53
For research use only. Not for use in diagnostic procedures.
Request more information
Robust library prep kit that generates high-complexity libraries for NGS on Illumina and Element platforms.
NEXTFLEX Rapid Directional RNA-Seq Kit 2.0
Robust library prep kit that generates high-complexity libraries for NGS on Illumina and Element platforms.
Robust library prep kit that generates high-complexity libraries for NGS on Illumina and Element platforms.

Loading...

Quick links
  • Variants
  • Product information
  • FAQs
  • Resources
  • SDS, COAs, manuals and more
  • Related reagents
  • Related products
  • Get help

Product information

  • Overview
  • Additional product information
  • Specifications
  • Citations

Overview

  • High coverage uniformity with low sequence duplication in the tested libraries
  • Input flexibility – 5 ng – 5 µg total RNA or 5 ng – 1 µg rRNA-depleted RNA
  • Reverse transcriptase and cleanup/size-selection beads are supplied in-kit
  • Tested with NEXTFLEX Poly(A) Beads 2.0 and NEXTFLEX RiboNaut rRNA Depletion for directional detection of coding and non-coding transcripts (including lncRNA)
  • Works with NEXTFLEX RNA-Seq 2.0 UDI barcodes for 2 – 384-plex runs or 96-plex UDI-UMI adapters to curb PCR duplicates
  • Automation-ready
  • Compatible with Illumina and Element Biosciences AVITI sequencers

Additional product information

Uniform coverage and low sequence duplication

The consistent read depth across exons delivered by the NEXTFLEX Rapid Directional RNA-Seq Kit 2.0  improves the reliability of differential-expression calls and isoform quantification and enables improved detection of long or GC-rich transcripts without the need for bioinformatic smoothing or extra sequencing depth to compensate for bias.

Line graph showing flat 5′ to 3′ gene-body coverage for NEXTFLEX RNA-seq Kit 2.0 versus 3′-biased competitor

Figure 1. The NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 demonstrates even coverage along transcripts compared to the Competitor N kit.

Figure 2 compares sequence-duplication rates estimated with fastp in the tested libraries. Sequence duplication alone does not distinguish PCR duplicates from independently sampled molecules or directly measure molecular library complexity.

Bar chart comparing sequence-duplication rates for NEXTFLEX and Competitor N at 100 ng and 10 ng RNA inputs.

Figure 2. The NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 showed lower sequence duplication than Competitor N in the tested poly(A)-enriched Universal Human Reference RNA libraries. Duplication was estimated with fastp after downsampling to 100,000 reads.

For more information & data, check out our application note here.

Flexible input range and ready-to-use reagents

From low-nanogram inputs harvested from precious biopsy samples to microgram quantities from cultured cells, the NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 streamlines the workflow, so you can progress from RNA to libraries with minimal additional setup. Reverse-transcription and size-selection chemistries are optimized to maintain uniform coverage and high library complexity across this entire input span, allowing a single protocol to serve both low-input discovery projects and high-throughput expression studies.

Seamless integration with NEXTFLEX accessories

The NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 plugs straight into Revvity’s wider NEXTFLEX RNA-seq accessory portfolio, letting you tailor each run to your sample type and throughput. Upstream choices include Poly(A) Beads 2.0 for fast mRNA enrichment and RiboNaut rRNA Depletion for total-RNA or degraded-sample workflows. Downstream, RNA-Seq 2.0 UDI adapter plates support up to 384-plex studies, while UDI-UMI adapter plates support up to 96-plex studies with molecular barcodes for UMI-based analysis. Every batch is color-balanced and QC-verified for index purity, protecting you from barcode bleed-through in large pools.

Explore the full accessory line to build a workflow that scales from low-input discovery to high-throughput clinical research without swapping vendors or protocols. For plant transcriptomics, the NEXTFLEX Rapid Directional RNA seq Kit 2.0 has been successfully paired with the Pan Plant riboPOOL to remove plant rRNA.

Automation-ready with 30 minutes of hands-on time

Pre-built scripts for the Sciclone G3 NGSx and Zephyr G3 NGS workstations cut hands-on time to <30 min for a full 96-well plate while preserving the coverage and duplicate metrics shown in Figures 1 and 2. That makes the workflow ideal for core labs balancing speed, reproducibility, and walk-away convenience.

Power your functional-genomics workflow with Revvity gene-modulation reagents

From hypothesis-free CRISPR-Cas9 knockout screens to precise CRISPRa/i activation or interference assays, Pin-point™ base editing, and well-established Dharmacon™ RNAi libraries, Revvity delivers every modality you need to probe gene function. Entire collections come in pooled or arrayed formats, to either increase or silence the expression levels of your gene of interest as part of your functional studies.

Synthetic sgRNA pools eliminate cloning and viral-packaging steps, while Pin-point™ base-editing reagents introduce precise, programmable single-nucleotide substitutions, an ideal approach for modeling disease alleles or drug-resistance mutations. Explore the complete CRISPR, RNAi, and base-editing portfolio.

Faster RNA-seq pooling for directional workflows

Use NEXTFLEX NGS Library Normalization Beads after PCR to standardize molarity across rRNA-depleted and poly(A)-selected libraries. You can pool immediately without separate quantitation, which helps keep large, multiplexed studies on schedule while maintaining even read counts across samples.

Specifications

Automation Compatible
Yes
Format
Manual
Product Group
RNA-seq
Shipping Conditions
Dual Temperature
Unit Size
8 rxns

Citations

De novo transcriptomes & non-model-organism genomics

  • Bond, D. M., Ortega-Recalde, O., Laird, M. K., et al. (2023). The admixed brushtail possum genome reveals invasion history in New Zealand and novel imprinted genes. Nature Communications, 14, 6364. https://doi.org/10.1038/s41467-023-41784-8
  • Gaonkar, C. C., & Campbell, L. (2023). De novo transcriptome assembly and gene annotation for the toxic dinoflagellate Dinophysis. Scientific Data, 10, 345. https://doi.org/10.1038/s41597-023-02250-8
  • Smith, C. H., Mejia-Trujillo, R., Breton, S., Pinto, B. J., Kirkpatrick, M., & Havird, J. C. (2023). Mitonuclear sex determination? Empirical evidence from bivalves. Molecular Biology and Evolution, 40(11), msad240. https://doi.org/10.1093/molbev/msad240
  • Chen, C., Tjeng, R., & Mueller, J. (2024). De novo transcriptome assembly and gene annotation for the toxic dinoflagellate Karenia. Scientific Data, 11, 34. https://doi.org/10.1038/s41597-023-02250-8
  • Feke, A., Vaillancourt, B., Acheson, K., et al. (2025). High resolution diel transcriptomes of autotetraploid potato reveal expression and sequence conservation among rhythmic genes. BMC Genomics. 26(1):925. https://doi.org/10.1186/s12864-025-11945-8.

Disease & functional-genomics models

  • Laudadio, I., Carissimi, C., Scafa, N., et al. (2024). Characterization of patient-derived intestinal organoids for modelling fibrosis in inflammatory bowel disease. Inflammation Research, 73, 1359–1370. https://doi.org/10.1007/s00011-024-01901-9
  • Manukjan, N., Chau, S., Caiment, F., et al. (2024). Wnt7a decreases brain endothelial barrier function via β-catenin activation. Molecular Neurobiology, 61, 4854–4867. https://doi.org/10.1007/s12035-023-03872-0
  • Tóvári, J., Vári-Mező, D., Surguta, S. E., Ladányi, A., Kígyós, A., & Cserepes, M. (2023). Evolving acquired vemurafenib resistance in a BRAF V600E mutant melanoma PDTX model to reveal new potential targets. Cells, 12, 1919. https://doi.org/10.3390/cells12141919
  • McCarlie, S., Boucher-van Jaarsveld, C., & Bragg, R. (2024). Differential expression analysis reveals possible new quaternary ammonium compound resistance gene in highly resistant Serratia sp. HRI. Microorganisms, 12(9), 1891. https://doi.org/10.3390/microorganisms12091891 
  • RNA chemistry, translation & isoform diversity
  • Mulroney, T. E., Pöyry, T., Yam-Puc, J. C., et al. (2024). N1-methylpseudouridylation of mRNA causes +1 ribosomal frameshifting. Nature, 625, 189–194. https://doi.org/10.1038/s41586-023-06800-3
  • Higdon, A. L., Won, N. H., & Brar, G. A. (2024). Truncated protein isoforms generate diversity of protein localization and function in yeast. Cell Systems, 15(4), 388–408.e4. https://doi.org/10.1016/j.cels.2024.03.005
  • Grossi, E., Nguyen, C.B., Carcamo, S., et al. (2025). The SWI/SNF PBAF complex facilitates REST occupancy at repressive chromatin. Mol Cell. 85(9):1714-1729.e7. https://doi.org/10.1016/j.molcel.2025.03.026.
  • Bajtai E., Kiss, C., Bakos, É., et al. (2025). Therapy-induced senescence is a transient drug resistance mechanism in breast cancer. Mol Cancer. 24(1):128. https://doi.org/10.1186/s12943-025-02310-0.

Stable non-coding RNA / aging

  • Kirio, K., Patop, I. L., Martin Anduaga, A., Harris, J. M., Pamudurti, N., Su, T. N., Martel, C., Kadener, S. (2025). Circular RNAs exhibit exceptional stability in the aging brain and serve as reliable age and experience indicators. Cell Reports, 44(1), 115485. https://doi.org/10.1016/j.celrep.2025.115485

FAQs

  • What types of RNAs are going to be detected with the NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 library?

    The NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 is a total RNA sequencing workflow that will capture any RNA with length > 200 nucleotides present in your sample. It uses random primers for cDNA synthesis and will be compatible with RNA from any species, both prokaryotes and eukaryotes. For transcripts with length < 200 nucleotides, please check our NEXTFLEX Small RNA seq Kit v4 or contact our technical support team.

  • What is the starting material I need to use to prepare libraries with this kit?

    The starting material is Total RNA (minimum 5 ng), previously isolated mRNA (minimum 1 ng) or ribosomal-depleted RNA (minimum 5 ng).

  • Are the libraries produced by NEXTFLEX Rapid Directional RNA-seq 2.0 stranded?

    Yes. The libraries generated by the NEXTFLEX Rapid Directional RNA-seq 2.0 kit incorporate dUTP during the second-strand synthesis step. During library amplification, the strand containing dUTP is not amplified, allowing retention of the original strand’s orientation.

  • Is this kit compatible with RNA enrichment?

    Yes. The NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 is a total RNA workflow compatible with downstream target enrichment.

  • Do you offer solutions for depletion of rRNA, globin and others?

    Yes. The NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 kit can be combined with modular RNA enrichment or depletion accessories. NEXTFLEX Poly(A) Beads 2.0 use oligo(dT) capture to enrich polyadenylated RNA. NEXTFLEX RiboNaut rRNA Depletion uses targeted hybridization to remove rRNA while retaining polyadenylated and non-polyadenylated transcripts. CRISPR/Cas9-based depletion is another option. Please contact the Revvity technical support team to discuss the best solution for your project.

  • Is this kit compatible with FFPE-derived/low-quality RNA?

    Yes. The NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 is a total RNA workflow compatible with any RNA regardless of its integrity. When RNA quality is low, we recommend using the kit with either NEXTFLEX RiboNaut rRNA depletion or CRISPR/Cas9-based rRNA depletion. This will remove rRNA while retaining exonic, intronic and intergenic regions. Please bear in mind that poly(A) capture is incompatible for use with degraded RNA, as there is the possibility of strand breaks between the 3' polyadenylated region and the rest of the transcript.

  • Can this kit be used to study long non-coding RNA?

    Yes. The NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 has already been used in different studies involving lncRNA. LncRNA can be polyadenylated or non-polyadenylated, so for these kinds of studies we recommend combining the kit with NEXTFLEX RiboNaut rRNA depletion even if RIN > 7. Please contact Revvity technical support team to discuss your project and to have detailed recommendations.

  • Can this kit be used to study circular RNA?

    Yes. The NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 has been already used in studies of CircRNAs. CircRNAs are present at low levels, needing enrichment to improve detection. RNase R is a 3′ to 5′ exonuclease commonly used upstream to degrade linear RNA, while sparing circular RNAs due to their closed-loop structure. Treated material can then be used as input for the NEXTFLEX kit. Please contact Revvity technical support team to discuss your project and to have detailed recommendations.

  • What kind of barcodes can be used with the NEXTFLEX Rapid Directional RNA-seq 2.0?

    The kit is compatible with barcoded adapters that bind to the insert by T-A ligation. We offer full-length Unique Dual Indexes (up to 384 different barcodes) and UDI-UMI (up to 96 different barcodes).

  • Does this kit support long-read sequencing?

    No. The use of random priming during first-strand synthesis does not support full-length cDNA generation, making it unsuitable for long-read applications.

  • What are the recommended settings for sequencing?

    Paired-end 2×150 bp sequencing is supported. Whether the reads cover the entire insert depends on the insert length and the usable read lengths after trimming. Single-end or paired-end sequencing is possible; select the format and read length for your analysis.

  • What is the number of reads required for RNA sequencing?

    The number of reads required for RNA sequencing typically ranges from 10 to 100 million reads per sample. This range can vary depending on the specific goals of your experiment. For example differential gene expression or discovery typically require greater numbers of reads. In addition, the complexity of the input tissue and amount of starting mRNA (or other target RNAs) may require a higher number of sequencing reads. If in doubt, please contact the Revvity technical support team for additional information on your particular project.

  • What do I need to do to run the NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 libraries on the AVITI™ sequencer from Element® Biosciences?

    This kit can run natively on Element Cloudbreak™ Freestyle Sequencing Kits, without any extra step.

Resources

Are you looking for resources, click on the resource type to explore further.

  • - Any -
  • Application Note:-:2
  • Flyer:-:1
  • Guide:-:1
  • Whitepaper:-:1
1-1 of 1 Resources
Whitepaper Icon
Whitepaper
Driving innovation in biopharmaceutical cell line engineering with transcriptomics

Explore the science behind smarter clone selection and how RNA-seq transforms cell line development with Revvity´s white paper.

Learn more

Loading...

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Revvity Logo

©2026 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.

Scroll Icon