Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • ゲノム解析
  • ライブラリー調製キット
  • NEXTFLEX Custom Small RNA Blockers

NEXTFLEX Custom Small RNA Blockers

NEXTFLEX NGS Library Prep
NEXTFLEX Custom Small RNA Blockers
NEXTFLEX NGS Library Prep
NEXTFLEX NGS Library Prep
NEXTFLEX NGS Library Prep

NEXTFLEX™ Custom Small RNA Blockers are sequence-specific oligos that can deplete the high-abundance small RNAs you specify, such as tRNA or Y RNA fragments and overexpressed miRNAs, to free up read depth for rare, study-relevant transcripts and increase library complexity. They work at the 3' adapter-ligation step of the NEXTFLEX Small RNA-Seq Kit v4 workflow, and support designs with up to 10 targets per project (25 – 50 nt), for any organism.

View product information
Feature Specification
Product Group Small RNA Accessory

NEXTFLEX™ Custom Small RNA Blockers are sequence-specific oligos that can deplete the high-abundance small RNAs you specify, such as tRNA or Y RNA fragments and overexpressed miRNAs, to free up read depth for rare, study-relevant transcripts and increase library complexity. They work at the 3' adapter-ligation step of the NEXTFLEX Small RNA-Seq Kit v4 workflow, and support designs with up to 10 targets per project (25 – 50 nt), for any organism.

View product information
Product variant
Unit Size: 1 unit
Part #:
NOVA-51313-01

For research use only. Not for use in diagnostic procedures.

Request more information
NEXTFLEX NGS Library Prep
NEXTFLEX Custom Small RNA Blockers
NEXTFLEX NGS Library Prep
NEXTFLEX NGS Library Prep
NEXTFLEX Custom Small RNA Blockers
NEXTFLEX NGS Library Prep
Quick links
  • Product information
  • FAQs
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Recently viewed
  • Get help

Product information

  • Overview
  • Additional product information
  • Specifications

Overview

NEXTFLEX Custom Small RNA Blockers let you deplete specific high-abundance small RNAs so more reads are allocated to study-relevant transcripts. Designed for use with the NEXTFLEX Small RNA-Seq Kit v4, they support flexible designs across organisms and sample types.

  • Targets up to 10 user-selected sequences per project (25 – 50 nt)
  • Applied at the 3' adapter-ligation step of the NEXTFLEX Small RNA-Seq Kit v4 workflow
  • Depletes unwanted species such as tRNA and Y RNA fragments or overexpressed miRNAs
  • Helps increase effective library complexity and read utilization in small RNA-seq
  • Compatible with default tRNA/YRNA Blockers and with NEXTFLEX blood miRNA blockers
  • Submit target sequences in FASTA format; ships lyophilized with use instructions

Additional product information

Maximize discovery by reducing dominant RNA species in small RNA-Seq

Small RNA sequencing profiles a wide array of RNA molecules under 200 nucleotides, including microRNA (miRNA), tRNA, Y RNA, PIWI-interacting RNA (piRNA), and more. However, in many samples, a few highly abundant RNA species, particularly tRNA fragments, Y RNA fragments, and a handful of overexpressed miRNAs dominate read counts. This skewed abundance profile reflects real biology but reduces library complexity, making it harder to detect rare yet biologically important RNAs.

Stop abundant RNAs from taking over your small RNA-seq data. NEXTFLEX Custom Small RNA Blockers selectively remove high-abundance RNAs from your libraries without affecting other sequences.

  • Affordable and tailored for your project. Target specific miRNAs, tRNA fragments, rRNA fragments, or Y RNAs from any organism.
  • Compatible with NEXTFLEX Small RNA-seq Kit v4.
  • Reduce unwanted sequences without introducing bias in other RNAs.
  • Free up sequencing capacity for the RNAs that matter most to your study.

How it works

  • Blockers are sequence-specific oligonucleotides designed to hybridize up to 10 unique target sequences chosen by the user. Target sequences must have a length of 25 - 50 nt.
  • Blocking occurs in the first step (Step A) of the NEXTFLEX Small RNA-Seq Kit v4 workflow.
  • Hybridized RNAs cannot undergo 3' adapter ligation, preventing amplification downstream.

Get started

Schedule a consultation or contact our team to design custom blockers for your species, tissue, or experimental context. Increase the complexity, sensitivity, and value of your small RNA sequencing today.

Specifications

Product Group
Small RNA Accessory
Shipping Conditions
Shipped in Dry Ice
Unit Size
1 unit

FAQs

  • In what format should I send the target sequences?

    Please submit target sequences in FASTA format.

  • How are the custom blockers shipped?

    Blockers are shipped lyophilized with instructions for resuspension and use. Each blocker ships in a separate tube; users may pool them equimolarly or at custom ratios.

  • When are the custom blockers used?

    Add the blockers at Step A of the workflow, during the 3' ligation step of the NEXTFLEX Small RNA-Seq Kit v4 workflow.

  • Do the custom small RNA blockers work with t/YRNA blockers?

    The existing tRNA/YRNA Blockers provided with the kit by default are designed against human, mouse and rat, and can be excluded or added in parallel with the custom blockers, depending on the research goals.

  • Do the custom small RNA blockers work with NEXTFLEX blood miRNA blockers?

    Yes. The blood miRNA blockers NEXTFLEX blood miRNA blockers Discover  deplete common miRNAs in whole blood and plasma. They can be used in parallel, or incorporated into a custom design if needed.

  • Do you guarantee complete depletion?

    Efficiency depends on sequence accessibility and sample type; we do not guarantee a specific depletion level.

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Form:-:1
1-1 of 1 Resources
Form Icon
Form
NEXTFLEX custom small RNA blocker request form

This form is used to fill in the required details to design Custom Small RNA Blockers.

Learn more

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.