Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • ゲノム解析
  • ライブラリー調製キット
  • NEXTFLEX 16S V3 – V4 Amplicon-Seq Library Prep Kit

NEXTFLEX 16S V3 – V4 Amplicon-Seq Library Prep Kit

NEXTFLEX NGS Library Prep
NEXTFLEX 16S V3 – V4 Amplicon-Seq Library Prep Kit
NEXTFLEX NGS Library Prep
NEXTFLEX NGS Library Prep
NEXTFLEX NGS Library Prep

The NEXTFLEX™ 16S V3-V4 Amplicon-Seq Kit prepares sequencing libraries that amplify the V3 and V4 hypervariable regions of the 16S rRNA gene for microbiome profiling. A two PCR workflow with minimal cleanups maximizes recovery. Libraries are compatible with paired-end 2×300 runs on Illumina® MiSeq® and Element® Aviti® instruments, with overlapping reads across V3-V4 for improved taxonomic assignment. Typical input is 1 – 50 ng of DNA, enabling a fast, reliable amplicon sequencing workflow for bacterial community profiling. The V3-V4 design provides broad bacterial coverage and works with established reference databases and analysis pipelines. Overlapping reads enable confident amplicon sequence variant calling.

Kits include cleanup beads and up to 96 barcoded (384 available upon request) PCR II primers for high throughput indexing and pooling. In the product listing, “S” variants add access to 16S analysis through Cosmos-Hub, which runs a DADA2-based pipeline with SILVA taxonomy to deliver quality-controlled ASV tables and interactive visualizations.

View product information
Feature Specification
Automation Compatible Yes
Product Group 16S amplicon-seq

The NEXTFLEX™ 16S V3-V4 Amplicon-Seq Kit prepares sequencing libraries that amplify the V3 and V4 hypervariable regions of the 16S rRNA gene for microbiome profiling. A two PCR workflow with minimal cleanups maximizes recovery. Libraries are compatible with paired-end 2×300 runs on Illumina® MiSeq® and Element® Aviti® instruments, with overlapping reads across V3-V4 for improved taxonomic assignment. Typical input is 1 – 50 ng of DNA, enabling a fast, reliable amplicon sequencing workflow for bacterial community profiling. The V3-V4 design provides broad bacterial coverage and works with established reference databases and analysis pipelines. Overlapping reads enable confident amplicon sequence variant calling.

Kits include cleanup beads and up to 96 barcoded (384 available upon request) PCR II primers for high throughput indexing and pooling. In the product listing, “S” variants add access to 16S analysis through Cosmos-Hub, which runs a DADA2-based pipeline with SILVA taxonomy to deliver quality-controlled ASV tables and interactive visualizations.

View product information
Product variants
Unit Size: 96 rxns
Analysis
Included
Barcodes
1 - 48
Part #:
NOVA-4204-03S
Unit Size: 192 rxns
Analysis
Included
Barcodes
1 - 96
Part #:
NOVA-4204-04S
For research use only. Not for use in diagnostic procedures.
Request more information
NEXTFLEX NGS Library Prep
NEXTFLEX 16S V3 – V4 Amplicon-Seq Library Prep Kit
NEXTFLEX NGS Library Prep
NEXTFLEX NGS Library Prep
NEXTFLEX 16S V3 – V4 Amplicon-Seq Library Prep Kit
NEXTFLEX NGS Library Prep
Quick links
  • Variants
  • Product information
  • FAQs
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Recently viewed
  • Get help

Product information

  • Overview
  • Additional product information
  • Specifications

Overview

  • Straightforward workflow: two PCR steps with minimal cleanups; no custom sequencing primers required.
  • Beads included: NEXTFLEX NGS Cleanup Beads come in the kit, so PCR cleanups are covered without a separate purchase, which can reduce consumables spend and simplify ordering.
  • Confident taxonomy calls: overlapping paired-end 2×300 reads across the V3-V4 amplicon on Illumina MiSeq and Element Aviti enable strong error correction and ASV recovery.
  • Flexible Input: validated conditions for 1 – 50 ng genomic DNA help maintain consistency across samples.
  • Scalable indexing: choose from 48 to 96 PCR II barcodes (384 available upon request) to match project size.
  • Built-in analysis option: SKUs with an “S” include Cosmos-Hub 16S analysis using DADA2 with SILVA, producing quality-controlled ASV tables and interactive reports.
  • Automation ready: methods available for Sciclone NGS and NGSx workstations, including G3 NGSx iQ.

Use this kit when you need reliable 16S V3-V4 library prep for standard 2×300 paired-end runs on Illumina MiSeq or Element Aviti, with a clean handoff to downstream analysis in Cosmos-Hub.

Additional product information

Simple 16S V3–V4 workflow, beads included, flexible multiplexing

The kit uses a two-PCR design. PCR I generates the V3–V4 amplicon from genomic DNA, then a bead cleanup removes primers and small fragments. PCR II adds the barcoded PCR II primers for indexing, followed by a final cleanup and pooling.

NEXTFLEX NGS Cleanup Beads are supplied with the kit. This helps reduce variability and avoids separate consumables purchase.

Indexing scales with your study: choose 48 or 96 barcode sets, with expanded options available up to 384 unique PCR II barcodes (upon request). Each barcode includes two reactions.

Accurate V3–V4 taxonomic assignment with overlapping reads and flexible input

Paired-end 2×300 sequencing spans the ~610 bp V3–V4 library and yields overlapping forward and reverse reads. That overlap enables read merging, quality-aware error modeling, and chimera filtering, which improves separation of closely related taxa and reduces misclassification in downstream calls.

 Bar chart showing relative percentages of bacterial reads.


Figure 1: Population results displayed as the percentage of total 16S DNA present after sequencing the extracted Zymo Community Standard

Accurate assignment matters because it shapes the conclusions you report, including community composition, relative abundance, and changes across conditions. Using exact sequence variants instead of broad clusters improves resolution and comparability across studies, which is especially helpful for longitudinal designs, method validation, and meta-analysis.

The kit supports a practical input of 1–50 ng DNA, so typical extracts can go straight into PCR without extra concentration. To keep results consistent across that range, the protocol provides cycle-number guidance matched to input, which helps achieve sufficient yield while limiting over-amplification artifacts.

Not sure when to choose 16S or metagenomics for microbial work? Read a short comparison that outlines the tradeoffs.

Cosmos-Hub 16S analysis (included with “S” variants)

Product variants above with “S” in their SKU number include access to Cosmos-Hub, an online analysis platform that converts your 16S V3–V4 FASTQ files into interpretable results using a standardized, version-controlled workflow. You receive a QC-filtered ASV table with taxonomy, clear quality summaries, and publication-ready visualizations. Comparative analysis tools are built in, including tables, heatmaps, bar and stacked plots, multiple alpha and beta diversity metrics, abundance distribution views, differential abundance testing, and statistics between groups. Results export as tab-separated tables and PDFs, and each chart can be downloaded as PNG or SVG for downstream use . Learn more about Cosmos-Hub.

The benefits of analysis provided by Cosmos-Hub offer.

 

webinar


Revvity 16S rRNA analysis - online demonstration

Now you can schedule a one-on-one 30-minute online demonstration that will cover everything you need to know about the Cosmos-Hub® which is now available with Revvity’s NEXTFLEX™ 16S rRNA Amplicon-seq Kits. You will be able to see the analysis demonstrated and our experts will be able to answer any questions that you may have.

Automation-ready

Automation protocols are available for the Sciclone™ NGS and NGSx workstations, and the Sciclone NGSx iQ™ workstation supporting walkaway NGS library preparation and higher throughput in 96-well plates while reducing manual steps and variability.

Region options to fit your study

Revvity offers 16S library prep kits for V3–V4, V4, and V1–V3, so you can match the target region to your goals: choose V3–V4 when you want more phylogenetic signal across two adjacent hypervariable domains, pick V4 for the shortest and most widely standardized amplicon that fits common read lengths, or select V1–V3 when your assay or consortium prefers that region for higher precision in certain clades or to align with established SOPs.

Specifications

Analysis
Included
Automation Compatible
Yes
Barcodes
1 - 48
Product Group
16S amplicon-seq
Shipping Conditions
Shipped in Dry Ice
Unit Size
96 rxns

FAQs

  • What sequencing platforms and read lengths are supported?

    Libraries are compatible with paired-end 2×300 sequencing on Illumina® and Element® instruments, and they do not require custom sequencing primers.

  • What DNA input range does the kit support?

    The protocol is optimized for 1–50 ng of DNA. Cycle numbers are adjusted in the manual based on input to achieve sufficient yield while limiting over-amplification.

  • Do I need to buy separate cleanup beads?

    No. NEXTFLEX NGS Cleanup Beads are included, so PCR cleanups can be performed without sourcing additional beads.

  • Which indexes are included, and can I scale higher multiplexing?

    Indexing sets of 48 and 96 are available off the shelf. To expand multiplexing capacity up to 384 samples please contact us.

  • Which primers are used to target the V3–V4 region?

    PCR I uses a Revvity primer mix that targets the V3 and V4 hypervariable regions, includes degeneracy for broad bacterial coverage.

  • Can I use this kit for archaeal profiling?

    The V3–V4 primers are widely used for prokaryotic surveys, but this kit has been validated with bacterial genomic DNA. If archaeal detection is critical, evaluate performance on your sample type before scaling.

  • Why are paired-end 2×300 reads important for this V3–V4 kit?

    The V3–V4 library is approximately 610 bp. 2×300 reads provide overlapping reads for read-pair merging, model-based error correction, and chimera removal that support precise ASV-level taxonomic assignment.

  • What do the “S” variants include for data analysis?

    Product variants with “S” in the SKU include access to Cosmos-Hub 16S analysis that delivers a quality-controlled ASV table with taxonomy, clear QC summaries, and publication-ready visualizations. Exports are provided as tab-separated tables and PDFs compatible with common analysis tools.

  • Is the workflow compatible with automation?

    Yes. Pre-built scripts are available for Sciclone G3 NGS and NGSx workstations, including the Sciclone G3 NGSx iQ workstation, to streamline 96-well library preparation with walk-away operation. The included cleanup beads are compatible with liquid handlers.

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Application Note:-:1
  • Flyer:-:2
  • Guide:-:1
  • Infographic:-:1
  • Other:-:1
1-2 of 2 Resources
Flyer Icon
Flyer
End-to-end metagenomics solutions.

This flyer showcases Revvity's metagenomic portfolio as well as Cosmos-Hub award winning analysis solution.

Learn more
Flyer Icon
Flyer
Simplify your 16S library prep and analysis.

This flyer provides guidance on which NEXTFLEX metagenomic kit to use for microbial community profiling projects

Learn more

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.