Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • プラットフォームと自動化
  • イメージング
  • In vivo イメージング
  • In Vivo Imaging Reagents
  • IVISense Fluorescent Probes
  • IVISense Osteo 680 Fluorescent Probe (OsteoSense)

IVISense Osteo 680 Fluorescent Probe (OsteoSense)

IVISense™ fluorescent imaging probes
IVISense Osteo 680 Fluorescent Probe (OsteoSense)
IVISense™ fluorescent imaging probes
IVISense™ fluorescent imaging probes - optimized and validated on Revvity's IVIS® optical imaging platform
IVISense™ fluorescent imaging probes

Image and quantify osteoporosis, arthritis, cancer metastases, and other bone diseases, as well as normal bone growth and resorption, in vivo with IVISense™ Osteo Fluorescent Imaging probes (OsteoSense™).

IVISense Osteo probes are available in 3 wavelengths: 680, 750, and 800 nm.

View product information
Feature Specification
Unit Size 1 vial (10 doses)
Specificity Hydroxyapatite

Image and quantify osteoporosis, arthritis, cancer metastases, and other bone diseases, as well as normal bone growth and resorption, in vivo with IVISense™ Osteo Fluorescent Imaging probes (OsteoSense™).

IVISense Osteo probes are available in 3 wavelengths: 680, 750, and 800 nm.

View product information
Product variants
Wave Length: 680 nm
Part #:
NEV10020EX
Wave Length: 750 nm
Part #:
NEV10053EX
Wave Length: 800 nm
Part #:
NEV11105
For research use only. Not for use in diagnostic procedures.
Request more information
IVISense™ fluorescent imaging probes
IVISense Osteo 680 Fluorescent Probe (OsteoSense)
IVISense™ fluorescent imaging probes
IVISense™ fluorescent imaging probes - optimized and validated on Revvity's IVIS® optical imaging platform
IVISense Osteo 680 Fluorescent Probe (OsteoSense)
IVISense™ fluorescent imaging probes
Quick links
  • Variants
  • Product information
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Get help

Product information

  • Overview
  • Specifications

Overview

As opposed to other imaging modalities such as CT or x-ray which raise the risk of harmful irradiation to the subject, in vivo fluorescence imaging offers no radiation exposure concerns, and when performed with optimized hydroxyapatite-targeted probes such as IVISense Osteo, can image and quantify bone growth and elucidate the biology of bone remodeling.

IVISense Osteo NIR fluorescent bisphosphonate imaging probes are designed to bind with high affinity to hydroxyapatite (HA) both in vivo and in vitro. Since HA is known to bind pyrophosphonates and phosphonates as well as synthetic bisphosphonates with high affinity, IVISense Osteo agents offer a safe and easy way to assess the subtle bone mineral changes that occur in bone growth, bone loss, and in diseases that damage bone, using subtherapeutic doses for imaging.

IVISense Osteo 680 is excited by 668 ± 10 mn excitation light and emits at 687 ± 10 mn. Including IVISense Isteo 680 in careful experimental design allows for multiplexing with other channels and/or imaging times, and so can be paired with other probes to achieve maximum efficiency and flexibility in imaging.

Specifications

Brand
IVISense
Fluorescent Agent Type
Targeted
Imaging Modality
Fluorescence
Shipping Conditions
Shipped Ambient
Specificity
Hydroxyapatite
Storage Conditions
+2 to +8 °C
Therapeutic Area
Arthritis
Atherosclerosis
Bone loss
Cardiovascular
Hypertension
Oncology
Unit Size
1 vial (10 doses)
Wave Length
680 nm

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Application Brief:-:1
  • Application Note:-:2
  • eBook:-:1
  • Flyer:-:1
  • Guide:-:1
  • Protocol/SOP:-:1
  • Whitepaper:-:1
1-1 of 1 Resources
Application Note Icon
Application Note
Multiplex 2D imaging of NIR molecular imaging agents on the IVIS SpectrumCT platform

Epifluorescence (2D) imaging of superficially implanted mouse tumor xenograft models offers a fast and simple method for assessing...

Learn more

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.