Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States

Error message

The submitted value 14851 in the field_resource_type element is not allowed.
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • 細胞分析
  • Cell Counting and Image Cytometry
  • Cell Counting & Image Cytometry Instruments
  • Cellometer X2 Fluorescent Cell Viability Counter

Cellometer X2 Fluorescent Cell Viability Counter

The Cellometer™ X2 automated cell counter is optimized for brewing yeast, wine yeast, platelets and other small cells.

For research use only. Not for use in diagnostic procedures.
Part #: CMT-X2-S150
Imaging Modality:
Fluorescence, Brightfield
Request more information Request a quote
Cellometer X2 Fluorescent Cell Viability Counter
Cellometer X2 Fluorescent Cell Viability Counter
Cellometer X2 Fluorescent Cell Viability Counter
Cellometer X2 Fluorescent Cell Viability Counter
Cellometer X2 Fluorescent Cell Viability Counter
Cellometer X2 Fluorescent Cell Viability Counter
Request a quote Request more information
ビュー related products
Quick links
  • Customers also bought
  • Product information
  • Resources
  • Manuals and more
  • Related products
  • Related products
  • Recently viewed
  • Get help

Pick a product variant

Fluorescence, Brightfield
Imaging Modality: Fluorescence, Brightfield
Part #: CMT-X2-S150
Request information

Product information

  • Overview
  • Additional product information
  • Specifications

Overview

Our yeast automated cell counter, the Cellometer X2, can be up to five times faster than manual cell counting. The cell count, concentration, diameter, and % viability are automatically calculated and reported within less than 60 seconds.

The Cellometer X2 is optimized for live yeast cell concentration and viability counting. It can also be used for:

  • Platelets
  • Other small cells

Additional product information

Fluorescent analysis

Fluorescent dyes that stain DNA can be used to identify nucleated cells in a mixed cell population. Acridine orange (AO) is a nuclear staining (nucleic acid binding) dye permeable to both live and dead cells. It stains all nucleated cells to generate green fluorescence when imaged with the Cellometer X2.

Because mature mammalian red blood cells don’t contain nuclei, only mononuclear cells produce a fluorescent signal. Fluorescent-positive nucleated cells are easily counted. There is no need to lyse red blood cells, saving time and eliminating an extra sample preparation step.

x4 nucleated cell counting
With propidium iodide (PI), dead cells are clearly visible in the red fluorescence channel

Use of a fluorescent dye, such as propidium iodide (PI), is highly recommended for accurate viability analysis of cell samples containing debris.

Propidium iodide (PI) is a nuclear staining (nucleic acid binding) dye that enters dead cells with compromised membranes. It stains all dead nucleated cells to generate red fluorescence.

Because the Cellometer X2 can count dead cells in the red fluorescence channel, there is no interference from debris and live cells.

fluorescent viability determination
1-Step yeast concentration & viability analysis using Cellometer X2

Brightfield and fluorescent imaging

The Cellometer X2 Image Cytometer performs simple, 1-step determination of yeast concentration and viability. The Cellometer X2 is useful for research laboratories looking to automate fermentation monitoring.

Brightfield images can be viewed to confirm cell morphology. Counted brightfield images show counted cells within cell clumps. Fluorescent images show dead cells for confirmation of viability results. Analysis of both brightfield and fluorescent images from each sample makes 1-step concentration & viability determination possible.

1-step yeast concentration viability

Brightfield and fluorescent images of yeast cells. Cells appearing in both the brightfield and fluorescent image are dead.

Exclusion of debris & size-based cell counting

Because Cellometer recognizes cells based on size, brightness, and morphology, cellular debris is easily and accurately excluded from counting results.

  • Cell size parameters can be modified to optimize exclusion of debris from results and enhance the accuracy of counting for a wide range of cell sizes.
  • A fluorescent nuclear dye, such as acridine orange, can be used to more easily identify nucleated cells in samples containing debris.
cell size histogram

The Cellometer X2 Image Cytometer automatically generates a cell size histogram based on cell diameter.

cell count optimized to exclude debris

The minimum and maximum cell diameter settings can be optimized to count specific cells in a sample.

Dynamic range of total cells with Cellometer X2

Concentration dynamic range figure 1 depicts the dynamic range for cell concentration measured by Cellometer X2. This data set was taken on a concentration series of cultured yeasts.

Samples from 2.5 x 105 - 5 x 107 cells/ml can be counted without further dilution.

The %CV at each concentration was below 10%.

dynamic range of total cells with X2

Figure 1: Table of results for cell concentration dynamic range.

Cellometer X2 repeatability and consistency

The results provide evidence of the increased accuracy of the Cellometer X2 instrument in assessing the viability of yeasts using AOPI for cell viability. Yeasts were tested at 24 sample replications. The viability average was calculated and plotted. The results show the reliability and accuracy of the Cellometer X2 in measuring cell concentration and viability of yeast cells.

Cellometer X2 Average live cell concentration via fluorescence Viability
AVE 1.32E+07 78.1%
STDEV 7.69E+05 2.2%
%CV 5.84 2.78


Table of results for cell concentration and viability using acridine orange (AO) and propidium Iodide (PI).
 

Cellometer X2 specifications
Includes
  • Cellometer X2 instrument
  • Cellometer software
  • Two standard fluorescence optics module
  • Power supply
  • USB 2.0 connection cable
  • Phone/online applications support during set-up
Available accessories
  • PC laptop
Imaging performance
  • Cell Size: 0.5 - 15 microns
  • Concentration Range: 5 x105 – 107 cells/ml
  • Brightfield imaging, fluorescent imaging and pattern-recognition software to quickly and accurately decluster, identify and count individual cells.
Instrument specifications
  • Weight: 23.0 lbs. (10.4 kg)
  • Dimensions: Width: 6.0” (15.2 cm), Depth: 8.5” (21.6 cm), Height: 14.0” (35.6 cm)
  • Input to power adapter: 100-240 VAC, 50/60 Hz, 1.0A
  • Output to instrument: 12 VDC, 3.34A

PC / Laptop minimum requirements:

(If purchasing Cellometer without PC laptop)

  • Windows 10
  • Intel® i5 (1.6 - 4.40 GHz) Processor
  • 10 Core
  • 4 GB RAM
  • Integrated Graphics Card
  • 1080p Display Resolution
  • 500 GB Hard Drive
  • USB 2.0 Port

 

Available fluorescence optics modules

VC-535-403

Excitation / Emission: 470nm/535nm

Example fluorophores:

  • Acridine Orange
  • CFDA
  • FITC

VC-660-503

Excitation / Emission: 540nm/660nm

Example fluorophores:

  • Propidium iodide (PI)
  • Ethidium bromide
  • 7-AAD

Specifications

Dimensions 6.0 in (W) x 8.5 in (D) x 14.0 in (H)
Weight
10.4 kg
Brand
Revvity
Imaging Modality
Fluorescence, Brightfield
Model
Cellometer X2 fluorescent cell viability counter
Technology
Cellometer Software
Unit Size
1 each

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Application Note:-:3
  • Brochure:-:3
  • Datasheet:-:1
  • eBook:-:2
  • Flyer:-:2
  • Literature - Publication Review:-:2
  • Scientific Poster:-:5
  • Specification Sheet:-:1
  • Whitepaper:-:6

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.