Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • 細胞分析
  • Cell Counting and Image Cytometry
  • Cell Counting & Image Cytometry Instruments
  • Cellaca MX ハイスループットセルカウンター

Cellaca MX ハイスループットセルカウンター

Cellaca™ MX ハイスループットセルカウンターは、明視野と2つの蛍光チャンネルを備えています。測定専用マイクロプレートを使用することで、最大 24 サンプルを蛍光測定を含み 2.5 分以内にカウントします。21 CFR Part 11 モジュールが利用可能です。

本製品は研究用です。診断用にはご使用いただけません。
Request a quote Request a demo Request more information
cellaca-MX-left-facing-from-top
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
cellaca-MX-left-facing-from-top
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
Video Play Button
Video Play Button
Video Play Button
Cellaca MX ハイスループットセルカウンター
cellaca-MX-left-facing-from-top
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
Video Play Button
Video Play Button
Video Play Button
cellaca-MX-left-facing-from-top
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
cellaca-MX-left-facing-from-top
Cellaca MX ハイスループットセルカウンター
cellaca-MX-left-facing-from-top
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
cellaca-MX-left-facing-from-top
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
Video Play Button
Video Play Button
Video Play Button
Part #: MX-AOPI
Imaging Modality:
蛍光・明視野
Request a quote Request a demo Request more information
ビュー related products
Quick links
  • Product information
  • Citations
  • FAQs
  • Resources
  • Manuals and more
  • Related products
  • Related products
  • Get help

Loading...

Product information

  • Overview
  • Additional product information
  • Specifications
  • Image gallery
  • Video gallery

Overview

Cellaca MX - 生産性の向上と、ワークフローの効率化を実現するハイスループット自動細胞カウンター

  • ハイスループット – 一度に最大24サンプルを実行可能
  • 少量サンプル - 必要な細胞サンプル量はわずか25 µL
  • オートフォーカス – 高速オートフォーカス
  • 細胞ベースのアッセイ – 単一細胞レベルでのデータ出力が可能。アポトーシスやミトコンドリア膜電位、たんぱく質発現(GFPやRFP等)、活性酸素種(ROS)などの細胞ベースのアッセイを実行可能
  • 経時変化のレポート – カスタマイズツールの使用で、複数サンプルの複数タイムポイントにおける増殖曲線を簡単に作成
  • 自動計算機能 – 使いやすいインターフェースで、ラベル付けされたサンプルごとに倍加時間などのデータも計算
  • 複数構成 – 蛍光フィルターを最大5 つまで追加可能
  • 自動化対応 – オプションのAPIによるロボットとの接続連携に対応
  • カスタマイズ可能なレポート – レポートにグラフ、画像、チャート、テーブルを追加可能
  • 多言語サポート – 7,000以上の言語に対応
  • 21 CFR Part 11対応 – 監査証跡、ユーザーアクセス制御、デジタル署名を含むオプションアドオンを提供

Additional product information

You don’t have to limit your experimental design

Run 24 samples in less than 3 minutes! No more reloading of individual slides or waiting for small batch counters to finish counting. With the Cellaca MX system your experiments are no longer limited by the throughput of your cell counting.

Multiple fluorescent filter options enable you to perform additional cell-based assays in minutes. With the Cell Fitness Panel you can get a quick check of the following cell health parameters:

  • Viability
  • Vitality
  • Apoptosis
  • Reactive oxygen species (ROS)
cellaca-2-sceens

Assay settings and cell type parameters ready to use

With the Cellaca MX cell counter you can build your own assays or choose from the many assays already included in the software. In addition, there are over 200 cell types preloaded with optimized settings. Simply find your assay and cell type in the menu and you are ready to count.

Cellaca-MX-cell types

Save time with simultaneous imaging and analysis

As soon as the first well has been acquired you can begin reviewing the images and data. No need to wait until the entire batch has been analyzed before starting to assess the results. Answers are available in seconds, not minutes. The ability to add additional automation with robotic integration can further help increase productivity.

cellaca-2-final

Figure 1. Wells in blue have been captured and analyzed. The green well is in progress of being analyzed. The orange well is next to be analyzed. Well A1 is selected and the AOPI image is displayed on screen (AO is green, PI is red). The report shows the number of live, dead and total cells counted for well A1.

Consistent and Dependable Results

The Cellaca MX system has undergone rigorous testing and verification to ensure reliable performance. In addition, the Cellaca MX counter can alert the operator when the cell count is out of range (too few or too many cells in the sample) and will suggest a corrective course of action (e.g., concentrating or diluting the cell sample and by how much).

Close correlation to hemocytometer

In this study, three tubes of 5-micron polystyrene beads were diluted to a concentration of ~2×106 beads/mL. To determine the concentration within each tube, 40 individual hemocytometer counts were performed for each tube. The Cellaca MX counter was then used to measure the concentration on the same set of tubes. The results show a very close correlation between the hemocytometer counted beads and the Cellaca MX counts.
 

Close correlation (1)

Figure 2. A total of 18 Revvity Counting Plates (432 wells) were used over the 3 tubes of beads and had average CV values of < 4%.
 

  Hemo CV Cellaca MX CV Hemo. Ave Cellaca MX Ave % Diff
Tube 1 4.46% 3.69% 2.03E+06 E.00E+06 1.20%
Tube 2 4.33% 3.64% 2.21E+06 2.16E+06 2.35%
Tube 3 4.28% 3.94% 2.10E+06 2.11E+06 0.71%

Table 2. The measured concentration differences between the Cellaca MX and the hemocytometer bead counts were between 0.7 – 2.35 %. 

Low plate-to-plate variability

In a study of 1,992 individually loaded samples (83 plates) by multiple users over multiple weeks a count of ~ 2×106 cells/mL CHO-s cells with Trypan blue yielded a CV less than 6% (figure 3). The cumulative counting time for all 83 plates was 70 minutes.

cellaca-average-cv

Figure 3. CHO cells stained with Trypan blue were shown to have a CV of 6% or less over 4 independent experiments totaling 83, 24-well plates (1,992 samples).

Consistent Viability Measurement using Fluorescence

Count messy samples more reliably with fluorescence! With the Cellaca MX 2FL and 5FL models, you can reduce red blood cells, platelets and debris from your counts using fluorescent nuclear stains. Acridine orange and propidium iodide are perfect for counting the nucleated cells in samples like PBMCs, patent samples, tumor digests and samples with lots of debris.

The advantage of fluorescent counting for primary cells

The images (Figure 4) demonstrate the advantage of fluorescent counting for primary cells. The bright field image shows the combination of nucleated cells, red blood cells and platelets present in the sample. Only the live and dead nucleated cells are visualized and counted in the green and red fluorescent channels.

fluorescent-primary

Figure 4. Several red blood cells are indicated in the bright field image (above, left). The red blood cells are not visible in the fluorescent image (above, right) detecting cells stained with nuclear staining dye.

Count Clumpy Cells using Declustering Algorithm

When working with clumpy cells you can apply declustering settings to identify and individually count each cell in your sample to increase the reliability of counts.

Clumpy cells

Figure 5. The above image shows cells counted with trypan blue on the Cellaca MX. The software automatically declusters and counts individual live cells (in green outlines) and Trypan blue positive dead cells (in red).

Customizable reports

Export reports as CSV, Excel, Word, or PDF files. Use default reports or customize based on the data and images you want included for the assay that was run. Statistical analysis can be included for various parameters. Different languages are available for reporting.

Cellaca-data-report
Mix the sample within the plate

Revvity’s proprietary patented* technology allows the user to mix the cell sample and the viability dye or staining reagent in a single well within the plate. The built-in capillary mechanism helps to ensure even distribution across the wells, which provides a completely processed sample set for imaging, counting, and analysis. There is no longer the need to perform these steps in a separate tube.

*U.S. Pat. No. 11,911,764; patents pending: EP3755789A1 and CN201980026197.7

Facilitates 21 CFR Part 11 compliance

An optional module can be purchased to help facilitate the FDA requirements for 21 CFR Part 11. The additional module comes with the following features:

  • User login with passwords
  • User-assigned permissions
  • Audit trail
  • Error log files
  • Electronic signatures

 

21CFRPart11

Cellaca MX high-throughput cell counter specifications

The Cellaca MX is available in different configurations. Each is field upgradeable to allow your instrument to configure to your experimental needs and quickly drive to deeper cellular insights.

  Cellaca MX BF Cellaca MX FL2 Cellaca MX FL5
Channels Brightfield Brightfield, Green, Red Brightfield, Blue, Green, Red, Far Red
Number of Channels 1 4 14
Excitation LED N/A 470, 527 365, 470, 527 and 620 nm
Emissions Filters N/A 534, 655 452, 534, 605, 655 and 692 nm
Commonly Used Compatible Dyes Trypan Blue Trypan Blue, AO/PI, GFP Trypan Blue, AO/PI, Hoechst, DAPI, GFP, RFP, CMFDA, Calcein AM, 7AAD, Annexin V
Counting Speed Per 24 Samples 48 seconds Trypan Blue - 48 seconds
Fluorescent - Less than 3 minutes
Trypan Blue - 48 seconds
Fluorescence - Less than 3 minutes
Volume (per well) 25 µL - 100 µL sample volume
50 µL - 200 µL total well volume
25 µL - 100 µL sample volume
50 µL - 200 µL total well volume
25 µL - 100 µL sample volume
50 µL - 200 µL total well volume
Size/Diameter Range  5 - 80 µm 5 - 80 µm 5 - 80 µm
Concentration Range 1x105 - 1x107 1x105 - 1x107 1x105 - 1x107
Fluorescence Upgradeable Yes Yes (add additional colors) N/A
IQ-OQ Option Yes Yes Yes
21 CFR Part 11 Ready Option Yes Yes Yes
Automation Compatible Yes Yes Yes
Operating System Windows 11 Windows 11 Windows 11
Dimensions 13 in x 13 in x 16 in
(33 cm x 33 cm x 41 cm)
 
13 in x 13 in x 16 in
(33 cm x 33 cm x 41 cm)
13 in x 13 in x 16 in
(33 cm x 33 cm x 41 cm)
Weight 40 lbs (18 kg) 42 lbs (19 kg) 42 lbs (19 kg)

Specifications

Dimensions 13.0 in (W) x 16.0 in (D) x 13.0 in (H)
Weight
19.1 kg
21CFR Compatible
Yes
Automation Compatible
Yes
Brand
Revvity
Imaging Modality
蛍光・明視野
Model
Cellaca MX ハイスループットセルカウンター
Technology
マトリックスソフトウェア
Unit Size
1 each

Image gallery

cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
Cellaca MX ハイスループットセルカウンター
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
Cellaca MX ハイスループットセルカウンター
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing
cellaca-MX-front-facing
cellaca-MX-left-facing
cellaca-MX-right-facing

Video gallery

Video Play Button
Video Play Button
Cellaca MX ハイスループットセルカウンター
Video Play Button
Video Play Button
Cellaca MX ハイスループットセルカウンター
Video Play Button
Video Play Button

Citations

FAQs

  • How much volume of my sample do I need to perform a count?

    The minimum loading volume of stained sample in the counting plate is 50 µl. Typically, you will stain your cell sample 1:1 with AOPI dual-fluorescent viability dye, so you can perform a cell count with as little as 25 µl of cell sample.

  • Can I save the plate for later if I only have a few samples to count?

    Yes, load the counting plate with as many or as few samples as you want to count. The Cellaca software will allow you to indicate which wells contain samples you wish to count and the rest of the plate can be saved for later use.

  • Are the counting plates compatible with multi-channel pipettes?

    Yes, the counting plates are compatible with multi-channel pipettes, making it fast and easy to stain and prep your samples. The Cellaca is also compatible with liquid handlers and automation platforms and has an optional automation license add-on, making it easy to scale up your throughput.

  • What daily start-up or shut-down cycles do I need to run?

    There are no daily start-up or shut-down cycles for the Cellaca because there are no internal fluidics and nothing that needs to get cleaned or could clog. The Cellaca uses LEDs as a light source. The only prep you need to do is turn on the instrument and start up the software, and the Cellaca is ready to count your samples right away.

  • How does the Cellaca count challenging or messy cell types?

    The Cellaca is designed to identify live and dead nucleated cells, even in very messy samples with RBCs and debris or in irregular-shaped cell populations. By using the AOPI dual-fluorescence viability dye, only nucleated cells are counted and RBCs and debris are ignored (this method is so specific, it even works in whole blood without lysing!). The Cellaca will show you the images it captured and which cells were counted so that you can visually verify the results and trust your data.

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Application Note:-:11
  • Article:-:7
  • Brochure:-:1
  • eBook:-:7
  • Flyer:-:2
  • Infographic:-:1
  • Literature - Publication Review:-:3
  • Scientific Poster:-:2
  • Specification Sheet:-:2
  • Technical Note:-:1
  • Whitepaper:-:1
31-36 of 38 Resources
Whitepaper Icon
Whitepaper
Practical cell counting method selection to increase the quality of results based on ISO cell counting standards

The importance of cell counting has increased significantly in the last decade due to the major advances in the fields of cell and...

Learn more
Publication Icon
Literature - Publication Review
Publication list for Cellometer, Cellaca and Celigo cell counting and image cytometry systems
Learn more
Flyer Icon
Flyer
Sources of variation in cell counting and how to avoid them
Learn more
Publication Icon
Literature - Publication Review
Streamlining single-cell sequencing workflows using Cellometer and Cellaca high-throughput cell counters

Streamlining single-cell sequencing workflows using Cellometer and Cellaca high-throughput cell counters

Single-cell sequencing...

Learn more
Whitepaper Icon
Whitepaper
The historical development of the hemacytometer

The hemacytometer has been an essential tool for hematologists, medical practitioners, and biologists for over a century. In this...

Learn more
Flyer Icon
Flyer
Time course graphing for improved workflow with the Cellaca MX high-throughput cell counter.
Learn more
Pagination
  • First page First
  • Previous page Previous
  • ページ 1
  • ページ 2
  • ページ 3
  • ページ 4
  • ページ 5
  • Current page 6
  • ページ 7
  • Next page Next
  • Last page Last

Loading...

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2026 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.