Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • タンパク質解析
  • イムノアッセイ
  • Alphaアッセイ
  • AlphaLISA SureFire Ultra Human Total SMARCA2 Detection Kit, 100 Assay Points

AlphaLISA SureFire Ultra Human Total SMARCA2 Detection Kit, 100 Assay Points

AlphaLISA Surefire Ultra Total Protein
Video Play Button
Video Play Button View All
AlphaLISA SureFire Ultra Human Total SMARCA2 Detection Kit, 100 Assay Points
AlphaLISA Surefire Ultra Total Protein
Video Play Button
Video Play Button
AlphaLISA Surefire Ultra Total Protein
AlphaLISA Surefire Ultra Total Protein
AlphaLISA Surefire Ultra Total Protein
AlphaLISA Surefire Ultra Total Protein
Video Play Button
Video Play Button

The AlphaLISA™ SureFire® Ultra™ Human Total SMARCA2 assay is a sandwich immunoassay for quantitative detection of total SMARCA2 in cellular lysates using Alpha technology.

View product information
Feature Specification
Application Cell Signaling
Sample Volume 30 µL

The AlphaLISA™ SureFire® Ultra™ Human Total SMARCA2 assay is a sandwich immunoassay for quantitative detection of total SMARCA2 in cellular lysates using Alpha technology.

View product information
Product variants
Unit Size: 100 assay points
Part #:
ALSU-TSMCA2-A-HV
Unit Size: 500 assay points
Part #:
ALSU-TSMCA2-A500
Unit Size: 10,000 assay points
Part #:
ALSU-TSMCA2-A10K
Unit Size: 50,000 assay points
Part #:
ALSU-TSMCA2-A50K
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption, and disposal requirements under European REACH regulations (EC 1907/2006).
Request more information
AlphaLISA Surefire Ultra Total Protein
AlphaLISA Surefire Ultra Total Protein
Video Play Button
Video Play Button
AlphaLISA SureFire Ultra Human Total SMARCA2 Detection Kit, 100 Assay Points
AlphaLISA Surefire Ultra Total Protein
Video Play Button
Video Play Button
AlphaLISA Surefire Ultra Total Protein
AlphaLISA Surefire Ultra Total Protein
AlphaLISA SureFire Ultra Human Total SMARCA2 Detection Kit, 100 Assay Points
AlphaLISA Surefire Ultra Total Protein
AlphaLISA Surefire Ultra Total Protein
Video Play Button
Video Play Button
Quick links
  • Variants
  • Product information
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Recently viewed
  • Customers also bought
  • Get help

Product information

  • Overview
  • How it works
  • Assay validation
  • Assay specificity/selectivity
  • Specifications
  • Video gallery

Overview

SMARCA2 (Probable global transcription activator SNF2L2), a member of the SWI/SNF family, plays a crucial role in chromatin remodeling and DNA damage repair. It serves as an ATPase subunit within the SWI/SNF complex, which regulates genes involved in DNA replication and cell proliferation. Notably, SMARCA2 and SMARCA4 are well-established in SMARCA4-deficient cancers, where SMARCA2 inactivation leads to tumor cell death. Considering its potential, SMARCA2 could be targeted for protein degradation therapeutics in cancer treatment.

The AlphaLISA SureFire Ultra Human Total SMARCA2 Detection Kit is a sandwich immunoassay for the quantitative detection of total SMARCA2 in cellular lysates, using Alpha technology.

Formats:

  • The HV (high volume) kit contains reagents to run 100 wells in 96-well format, using a 60 μL reaction volume.
  • The 500-point kit contains enough reagents to run 500 wells in 384-well format, using a 20 μL reaction volume.
  • The 10,000-point kit contains enough reagents to run 10,000 wells in 384-well format, using a 20 μL reaction volume.
  • The 50,000-point kit contains enough reagents to run 50,000 wells in 384-well format, using a 20 μL reaction volume.

AlphaLISA SureFire Ultra kits are compatible with:

  • Cell and tissue lysates
  • Antibody modulators
  • Biotherapeutic antibodies

Alpha SureFire kits can be used for:

  • Cellular kinase assays
  • Receptor activation studies
  • High-throughput drug screening

How it works

Total-AlphaLISA SureFire Ultra assay principle

The Total-AlphaLISA SureFire Ultra assay measures the expression level of a protein target in a cell lysate.

The Total-AlphaLISA SureFire Ultra assay uses two antibodies which recognize two different distal epitopes on the targeted protein. AlphaLISA assays require two bead types: Acceptor and Donor beads. Acceptor beads are coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody, labeled with a CaptSure tag. Donor beads are coated with streptavidin to capture one of the detection antibodies, which is biotinylated. In the presence of targeted protein, the two antibodies bring the Donor and Acceptor beads in close proximity whereby the singlet oxygen transfers energy to excite the Acceptor bead, allowing the generation of a luminescent Alpha signal. The amount of light emission is directly proportional to the quantity of protein present in the sample.

Assay Principle Total AlphaLISA SureFire Ultra

 

Total-AlphaLISA SureFire Ultra two-plate assay protocol

The two-plate protocol involves culturing and treating the cells in a 96-well plate before lysis, then transferring lysates into a 384-well OptiPlate™ plate before the addition of Total-AlphaLISA SureFire Ultra detection reagents. This protocol permits the cells viability and confluence to be monitored. In addition, lysates from a single well can be used to measure multiple targets.

2 plates assay protocol AlphaLISA Surefire Ultra Total assay

Total-AlphaLISA SureFire Ultra one-plate assay protocol

Detection of Total target protein with AlphaLISA SureFire Ultra reagents can be performed in a single plate used for culturing, treatment, and lysis. No washing steps are required. This HTS designed protocol allows for miniaturization while maintaining AlphaLISA SureFire Ultra quality.

1 plate assay protocol AlphaLISA Surefire Ultra Total assay

Assay validation

PROTAC induced SMARCA2 degradation

HeLa cells were seeded in a 96-well plate (40,000 cells/well) in complete medium, and incubated overnight at 37°C, 5% CO2. The cells were treated with ACBI1 at the indicated concentrations for 4 hours.

After treatment, the cells were lysed with 100µL of Lysis Buffer for 10 minutes at RT with shaking at 350 rpm. SMARCA2 and SMARCA4 Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate(approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision Nexus™ using standard AlphaLISA settings.

As expected, ACBI1 induced a dose-dependent decrease in both SMARCA2 and SMARCA4 levels.

PROTAC induced SMARCA2 degradation

Assay specificity/selectivity

Selectivity of SMARCA2 Total assay

Total SMARCA2 protein levels were assessed in HeLa cells (WT) and SMARCA2 knockout (KO) HeLa cells. SMARCA2 KO cells (Abcam ab265416) and WT-HeLa cells were seeded in a 96-well plate in complete medium, and incubated overnight at 37°C, 5% CO2. After treatment, the cells were lysed with 100 µL of lysis buffer for 10 minutes at RT with shaking (350 rpm). SMARCA2 Total levels were then evaluated by AlphaLISA SureFire Ultra. For the detection step, 10 µL of cell lysate was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision Nexus using standard AlphaLISA settings.As expected, SMARCA2 was detected in the WT-Hela cells but not in the SMARCA2-KO cell line.

Specificity of Total SMARCA2 assay

Total SMARCA2 expression levels were assessed in parallel with Total SMARCA4 in a panel of relevant cell lines. Lyophilized cell lysates from various cell lines were resuspended and then diluted in Lysis Buffer to ensure that detection was within the dynamic range of the kits (data not shown). SMARCA2 and SMARCA4 Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate was transferred into a 384- well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at room temperature. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision Nexus using standard AlphaLISA settings.

As expected, SMARCA2 and SMARCA4 expression is dependent upon cell type. SMARCA2 is expressed in THP1 and A549 cells, whilst SMARCA4 is undetectable. Conversely, SMARCA4 is expressed in Caco2 cells where SMARCA2 is undetectable. These results demonstrate the selectivity of the SMARCA2 assay over SMARCA4, despite these 2 proteins sharing more than 70% sequence identity.

Specificity of Total SMARCA2 assay

Selectivity of the Total SMARCA2 assay for SMARCA4 protein was assessed by assaying recombinant SMARCA4 protein. Dilutions of recombinant SMARCA4 protein (ab82237) were prepared in Lysis Buffer. SMARCA2 and SMARCA4 Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of protein was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at room temperature. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision Nexus using standard AlphaLISA settings.

As expected, the Total SMARCA2 signal was equivalent to the non-specific signal (dotted line). These results demonstrate the selectivity of the SMARCA2 assay over SMARCA4, despite these 2 proteins sharing more than 70% sequence identity.

Specificity of Total SMARCA2 assay

Specifications

Application
Cell Signaling
Automation Compatible
Yes
Brand
AlphaLISA SureFire Ultra
Detection Modality
Alpha
Host Species
Human
Lysis Buffer Compatibility
Lysis Buffer
Molecular Modification
Total
Product Group
Kit
Sample Volume
30 µL
Shipping Conditions
Shipped in Blue Ice
Target
SMARCA2
Target Class
Phosphoproteins
Target Species
Human
Technology
Alpha
Therapeutic Area
Neuroscience
Oncology
Unit Size
100 assay points

Video gallery

Video Play Button
Video Play Button
AlphaLISA SureFire Ultra Human Total SMARCA2 Detection Kit, 100 Assay Points
Video Play Button
Video Play Button
AlphaLISA SureFire Ultra Human Total SMARCA2 Detection Kit, 100 Assay Points
Video Play Button
Video Play Button

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Brochure:-:2
  • Guide:-:1
1-3 of 3 Resources
Guide Icon
Guide
AlphaLISA SureFire Ultra: the ultimate guide for successful experiments

The definitive guide for setting up a successful AlphaLISA SureFire Ultra assay

Several biological processes are regulated by...

Learn more
Brochure Icon
Brochure
Alpha SureFire Ultra no-wash immunoassay catalog

Discover Alpha SureFire® Ultra™ assays, the no-wash cellular kinase assays leveraging Revvity's exclusive bead-based technology...

Learn more
Brochure Icon
Brochure
Species compatibility for HTRF, AlphaLISA SureFire Ultra and Alpha SureFire Ultra Multiplex assays

This document includes detailed tables listing HTRF™, AlphaLISA™ SureFire® Ultra™, and Alpha SureFire® Ultra™ Multiplex assays...

Learn more

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.