Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • 細胞分析
  • Cell Counting and Image Cytometry
    • Cell Isolation
    • Cell Lines & Stem Cells
    • Cell Counting and Image Cytometry
    • セルヘルスと細胞生存率
    • Cellular Imaging & Analysis
    • Immunoassays
    • In Vivo Imaging
    • Microplates
  • Cell Counting & Image Cytometry Slides, Plates, and Beads
    • Cell Counting & Image Cytometry Slides, Plates, and Beads
    • Cell Counting & Image Cytometry Instruments
    • Cell Counting & Image Cytometry Reagents
  • Cell Counting Slides
    • Cell Counting Beads
    • Cell Counting Slides
    • High-throughput Cell Counting Plates

Cell Counting Slides

View products & services View resource library

Advantages of the Cellometer™ and Cellaca™ cell counting slides

  • No potential clogging
  • Ideal for fragile samples, such as hepatocytes
  • No washing
  • No potential cross-contamination


For research use only. Not for use in diagnostic procedures.

Request more information
img-cell-counting-slides-white-700x700.jpg
Slide: Compatible instrument(s): Cell size (µm): Sample load volume (µL): Key Attribute(s):
3-chamber Cellometer Ascend 5-80 20 Protective film on both sides needs to be removed before use, integrated autofocus feature
8-chamber Cellometer Ascend 5-80 10 Protective film on both sides needs to be removed before use
SD100 (2-chamber) Cellometer X2, Cellometer T4, Cellometer K2,
Cellometer Spectrum 5x and 10x
5-80 20 Protective film on both sides needs to be removed before use
PD100 (2-chamber) Cellometer X2, Cellometer T4, Cellometer K2,
Cellometer Spectrum 5x and 10x
5-80 20 Pre-peeled (no protective film) and ready-to-use, packaged in microscope slide box
PD300 (2-chamber) Cellometer K2, Cellometer T4, Cellometer Spectrum 5x >80 (i.e., adipocytes) 58 Pre-peeled (no protective film) and ready-to-use, packaged in microscope slide box
SD025 (2-chamber) Cellometer X2, Cellometer Spectrum 10x <20 (i.e., yeast, bacteria) 3 Protective film on both sides needs to be removed before use
Low fluorescence Cellaca PLX 2-80 15 Packaged individually in plastic sleeves, designed for fluorescent assays that require extra sensitivity
Disposable hemocytometer N/A, designed for manual microscope cell counting 2-80 20 Neubauer grid pattern for manual counting, packaged in microscope slide box

 

Featured products

1482979 8-up-slide-with-box 700x700
Cellometer Ascend 8-Chamber Slides
Part number: ASD-CHM8-001, ASD-CHM8-002
View details
1482979 3-up-slide-with-box 700x700
Cellometer Ascend 3-Chamber Slides
Part number: ASD-CHM3-001, ASD-CHM3-002
View details
of 2
bg-element-listing-page bg-element-listing-page-mobile
Products & services
Resource library
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.