Skip to main content
Revvity logo
Contact us
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Blog
  • NGS
  • Synthetic spike-in controls vs. mock microbial communities: what's the difference?
sequins blog hero

Synthetic spike-in controls vs. mock microbial communities: what's the difference?

  • NGS
  • NGS Library Prep

Nov 24th 2026

4 min read

Help us improve your Revvity blog experience!

Feedback

Reliable metagenomic analysis depends not only on sequencing depth but also on the ability to recognize and measure technical variability. Differences in DNA extraction efficiency, library preparation, sequencing, and bioinformatics can alter the microbial profiles obtained from the same biological sample. These effects become particularly important when comparing results across laboratories, sequencing runs, or longitudinal studies.

The scale of this challenge was illustrated by Forry and colleagues in a study involving 44 laboratories performing 16S rRNA gene or shotgun metagenomic sequencing. The study identified discrepancies between observed and expected abundances even when laboratories showed agreement with one another1.
 

Key takeaways:

  1. Mock microbial communities help identify biases in metagenomic workflows and benchmark analytical accuracy.
  2. Synthetic DNA spike-ins provide distinguishable internal references for quantitative normalization across samples and sequencing runs.
  3. Metagenomics-based Sequins™ support abundance calibration and assessment of detection and quantification limits.


Reference standards help researchers identify and assess these biases. Two widely used approaches are mock microbial communities and spike-in controls. Although their applications overlap, they differ in composition, implementation, and the information they provide. Understanding these differences is essential when selecting controls for metagenomic analysis.

Two approaches to metagenomic quality control

Mock microbial communities are defined mixtures of microorganisms or their genomic DNA, prepared at known abundances to benchmark metagenomic accuracy. Whole-cell communities can reveal biases in cell lysis and DNA recovery, while purified DNA mixtures help assess library preparation, sequencing, and bioinformatic analysis. McLaren and colleagues demonstrated reproducible, taxon-specific biases in microbial abundance measurements, highlighting the importance of defined reference materials for identifying and potentially correcting such effects2.

Mock communities are commonly processed alongside experimental samples as separate references. When added directly to samples, however, their naturally derived DNA may overlap with native microbial sequences, complicating identification and quantification.

Spike-in controls are introduced into individual samples at known quantities to monitor technical variability and support quantitative calibration. Whole-cell spike-ins added before extraction can help assess DNA recovery, whereas DNA-based controls introduced after extraction provide a reference for downstream analytical steps.

These approaches are not mutually exclusive, as distinguishable mock communities can also serve as spike-ins. Synthetic DNA controls offer an alternative by using engineered sequences designed to minimize overlap with natural microbial genomes, facilitating their identification and use for quantitative normalization.

Commercial reference controls and the Sequins Metagenomics Core Control Set

Commercial metagenomic controls differ in microbial diversity, composition, and intended application. The number of species represented, their distinguishability from native sample DNA, and the stage at which controls are introduced determine their suitability for different workflows (Table 1).
 

Control type What it contains How it is used Commercial example Species represented
Whole-cell mock community Defined mixture of microbial cells Processed as a separate control, starting before cell lysis and DNA extraction. ZymoBIOMICS™ Microbial Community Standard 10
Purified DNA mock community A defined mixture of microbial genomic DNA Processed as a separate control, starting at library preparation. ATCC 20-Strain Staggered Mix 20
Whole-cell spike-in Microbial cells Added to study samples before cell lysis and DNA extraction. The selected organisms must be distinguishable from those naturally present. ZymoBIOMICS™ Spike-in Controls I & II 2 (Control I), 3 (Control II)
Tagged DNA spike-in Microbial genomic DNA containing engineered 16S rRNA gene tags Added to extracted sample DNA before library preparation. Engineered 16S rRNA gene tags within the genomic DNA distinguish the control from native microbial DNA. The rest of the control genome may overlap with native sample DNA. ATCC Tagged Spike-in Standards 3
Synthetic DNA spike-in Artificial DNA sequences supplied at known abundances Added to extracted sample DNA before library preparation. Reads are assigned to artificial reference sequences, allowing the control to be measured separately from native microbial DNA. Sequins™ Metagenomics Core Control Set 52


Table 1. Types of metagenomic reference controls, their use in the workflow, and representative commercial examples.

The Sequins™ Metagenomics Core Control Set offers broad microbial sequence representation, with synthetic DNA sequences representing 52 microbial species across bacteria, archaea, and eukaryotes and a GC-content range of approximately 27–71%. Unlike biological controls, Sequins use mirrored genomic sequences that preserve nucleotide composition while minimizing homology with natural DNA, facilitating their identification during microbial profiling.

Building on the technology described by Hardwick and colleagues3, the set incorporates a quantitative molecular ladder with known concentrations spanning a broad dynamic range. By comparing observed sequencing coverage with known input quantities, researchers can assess quantitative linearity, support abundance normalization, and establish analytical detection and quantification limits under defined experimental conditions.

Hardwick and colleagues demonstrated improved quantitative normalization using metagenomics-based Sequins, revealing absolute abundance changes that normalization based only on genome size and sequencing depth could not resolve3. More recently, Davis and colleagues applied metagenomics-based Sequins to wastewater analysis, establishing experimental detection and quantification limits and demonstrating agreement with droplet digital PCR for selected genetic targets4. These studies support the underlying technology rather than directly validating the current commercial formulation.

The Sequins™ Metagenomics Core Control Set is added to purified DNA before library preparation, providing a reference for downstream analytical steps. Metagenome sequin controls have also been evaluated using Illumina® and Oxford Nanopore Technologies™ sequencing. As post-extraction standards, they do not measure upstream losses during sample processing or DNA extraction. Converting calibrated measurements into concentrations per unit of original sample also requires sample-volume information and consideration of nucleic acid recovery.

Conclusion

Mock microbial communities and spike-in controls address complementary aspects of metagenomic quality control. The appropriate choice depends on the experimental objective and the stages of the workflow that need to be evaluated. Whole-cell standards are particularly useful for assessing extraction-related variability, while defined DNA mixtures provide reference compositions for benchmarking downstream analytical accuracy.

For studies requiring quantitative comparisons across samples, sequencing runs, batches, or longitudinal time points, distinguishable synthetic DNA controls offer additional advantages. The Sequins™ Metagenomics Core Control Set combines broad synthetic microbial representation with a quantitative calibration ladder, providing an internal reference for quantitative shotgun metagenomics.
 

Discover the Sequins Metagenomics Core Control Set


References

  1. Forry SP, et al. Variability and bias in microbiome metagenomic sequencing: an interlaboratory study comparing experimental protocols. Scientific Reports. 2024;14:9785. https://doi.org/10.1038/s41598-024-57981-4
  2. McLaren MR, Willis AD, Callahan BJ. Consistent and correctable bias in metagenomic sequencing experiments. eLife. 2019;8:e46923. https://doi.org/10.7554/eLife.46923
  3. Hardwick SA, et al. Synthetic microbe communities provide internal reference standards for metagenome sequencing and analysis. Nature Communications. 2018;9:3096. https://doi.org/10.1038/s41467-018-05555-0
  4. Davis BC, Vikesland PJ, Pruden A. Evaluating Quantitative Metagenomics for Environmental Monitoring of Antibiotic Resistance and Establishing Detection Limits. Environmental Science & Technology. 2025;59:6192–6202. https://doi.org/10.1021/acs.est.4c08284

For research use only. Not for use in diagnostic procedures.

4 min read

Nov 24th 2026

Categories:
  • NGS
  • NGS Library Prep

続き NGS posts

sequins wastewater thumbnail
Improving quantification in wastewater metagenomics.
Read
blog mutation thumbnail
When no mutations are detected: why tumor fraction matters in liquid biopsy.
Read
multiomics blog thumbnail
Integrating small RNA-seq and single-cell multiomics to investigate tumor-T-cell communication.
Read

Help us improve your Revvity blog experience!

Feedback

Share this post:

  • Email
  • Facebook
  • Linkedin
  • Twitter
line

ご質問がございましたら、
お気軽にお問い合わせください。

お問合せ

Featured products

Sequins logo primary image
Sequins Metagenomics Core Control Set
Part number: NOVA-10008, NOVA-10009
View details
of 1
Revvity Logo

©2026 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.

Scroll Icon