Skip to main content
Revvity logo
Contact us
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Blog
  • NGS
  • Improving quantification in wastewater metagenomics.
sequins wastewater hero

Improving quantification in wastewater metagenomics.

  • NGS
  • NGS Library Prep

Nov 24th 2026

4 min read

Help us improve your Revvity blog experience!

Feedback

Wastewater-based metagenomics has grown from an exploratory method into an established complement to public health surveillance. Wastewater matrices contain a complex, dynamic mixture of microbial DNA that can reveal changes in community compositions and antimicrobial resistance.

Whole-genome sequencing (WGS) surveys this genetic material without restricting analysis to a predefined marker or target panel. A prominent example of the reach of this approach was demonstrated by Munk and colleagues, who analyzed 757 sewage samples from 101 countries, uncovering regional patterns in resistance genes and their genomic contexts1.
 

Key takeaways:

  • Synthetic DNA standards help measure absolute gene abundance and compare results across wastewater samples and over time.
  • Metagenome Sequins™ provide known reference concentrations to establish limits of detection and quantification.
  • Cellular spike-ins help assess DNA extraction efficiency, while synthetic DNA standards provide calibration after extraction.


For many wastewater studies, however, identifying genes is only part of the objective. Researchers increasingly need to determine whether a specific target’s concentration has changed between sampling dates, across treatment stages, or in response to localized interventions. Standard WGS results normalized to total reads or housekeeping marker genes only describe a target relative to the background sequenced community.

Changes in background microbial DNA can alter a target’s relative abundance even when its absolute concentration remains unchanged2.

Navigating reference standards in quantitative metagenomics

To bridge the gap between relative-abundance profiling and absolute quantification, researchers employ different types of reference standards that address distinct stages of the analytical workflow. Whole-organism or cellular spike-ins, including defined microbial mixtures, can be introduced before DNA extraction to monitor cell lysis efficiency and extraction recovery, as demonstrated by Shi and colleagues across different environmental matrices3.

However, biological controls may not fully represent the extraction behavior of all microorganisms within a complex sample. Alternatively, exogenous genomic DNA can be added to extracted nucleic acids to provide a post-extraction calibration baseline, as demonstrated by Crossette and colleagues2. While useful for absolute quantification, naturally derived genomic DNA standards may share sequence similarities with environmental microorganisms, complicating unambiguous read assignment.

Synthetic DNA standards, including metagenome Sequins™, offer an alternative specifically designed for downstream calibration. Pioneered by Mercer and colleagues, metagenome Sequins are artificial DNA sequences designed to reproduce properties of natural microbial genomes while remaining distinguishable from them4. By introducing these sequences at known concentrations, researchers can establish calibration curves and determine workflow-specific limits of detection and quantification5,6. The principles demonstrated in these studies can be applied in routine workflows using commercially available synthetic standards, such as the Sequins™ Metagenomics Core Control Set. Supplied as a ready-to-use mixture, this product contains synthetic sequences representing 52 microbial species across bacteria, archaea, and eukaryotes, with GC content ranging from 27% to 71%. The mixture also contains predefined concentration levels for quantitative calibration and can be added directly to extracted DNA before library preparation.

Davis and colleagues successfully applied metagenomics-based Sequins™ reference standards to wastewater DNA extracts from influent, activated sludge, and secondary effluent, demonstrating that quantitative metagenomics could produce gene concentration measurements and log-removal estimates statistically equivalent to those obtained by droplet digital PCR for selected targets5.

Complementary work by Langenfeld and colleagues led to the development of QuantMeta, an analytical framework that uses synthetic DNA standards to establish detection thresholds and identify and correct read-mapping errors in wastewater viromes6.

For WGS, workflows such as the NEXTFLEX™ Rapid XP v3 DNA-Seq Kit offer enzymatic fragmentation and a PCR-free preparation option when sufficient DNA input is available, providing an approach for processing metagenomic DNA alongside internal standards. However, the quantitative performance of each specific workflow must be validated, as detection limits and reliable quantification ranges depend on sample composition, sequencing depth, and bioinformatic analysis5,6.

Connecting calibrated measurements to wastewater concentrations

The stage at which a control enters the workflow dictates what it can measure. Cellular spike-ins introduced before extraction, such as those evaluated by Shi and colleagues, help assess lysis and extraction recovery3, while synthetic DNA standards added after extraction, such as the Sequins™ Metagenomics Core Control Set, support downstream calibration.

Converting calibrated sequencing measurements into gene copies per milliliter also requires tracking of original sample volume, final extract volumes, and the fraction of extract used for library preparation5. Without an independently established recovery correction, these concentrations remain estimates based on recovered DNA.
 

Bring a quantitative reference to your wastewater metagenomic workflow


References:

  1. Munk P, Brinch C, Møller FD, et al. Genomic analysis of sewage from 101 countries reveals global landscape of antimicrobial resistance. Nature Communications. 2022;13:7251. https://doi.org/10.1038/s41467-022-34312-7
  2. Crossette E, Gumm J, Langenfeld K, Raskin L, Duhaime M, Wigginton K. Metagenomic Quantification of Genes with Internal Standards. mBio. 2021;12(1):e03173-20. https://doi.org/10.1128/mBio.03173-20
  3. Shi X, Yang Y, Wang C, et al. Microbial risk assessment across multiple environments based on metagenomic absolute quantification with cellular internal standards. Nature Water. 2025;3:473–485. https://doi.org/10.1038/s44221-025-00421-y
  4. Hardwick SA, Chen WY, Wong T, et al. Synthetic microbe communities provide internal reference standards for metagenome sequencing and analysis. Nature Communications. 2018;9:3096. https://doi.org/10.1038/s41467-018-05555-0
  5. Davis BC, Vikesland PJ, Pruden A. Evaluating Quantitative Metagenomics for Environmental Monitoring of Antibiotic Resistance and Establishing Detection Limits. Environmental Science & Technology. 2025;59(12):6192–6202. https://doi.org/10.1021/acs.est.4c08284
  6. Langenfeld K, Hegarty B, Vidaurri S, Crossette E, Duhaime MB, Wigginton KR. Development of a quantitative metagenomic approach to establish quantitative limits and its application to viruses. Nucleic Acids Research. 2025;53(5):gkaf118. https://doi.org/10.1093/nar/gkaf118

For research use only. Not for use in diagnostic procedures.

4 min read

Nov 24th 2026

Categories:
  • NGS
  • NGS Library Prep

続き NGS posts

sequins blog thumbnail
Synthetic spike-in controls vs. mock microbial communities: what's the difference?
Read
blog mutation thumbnail
When no mutations are detected: why tumor fraction matters in liquid biopsy.
Read
multiomics blog thumbnail
Integrating small RNA-seq and single-cell multiomics to investigate tumor-T-cell communication.
Read

Help us improve your Revvity blog experience!

Feedback

Share this post:

  • Email
  • Facebook
  • Linkedin
  • Twitter
line

ご質問がございましたら、
お気軽にお問い合わせください。

お問合せ
Revvity Logo

©2026 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.

Scroll Icon