Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Resources
  • Knowledge Base
  • CellCountingSub Section
  • High-throughput Neutralization Assay of AAV-GFP Vectors Using Neutralizing Antibodies
Cell Counting and Image Cytometry

High-throughput Neutralization Assay of AAV-GFP Vectors Using Neutralizing Antibodies

Section
Cell-based Assays for Gene Therapy Development
Celigo Applications
Cell Counting Method Selection
Cell Counting and Image Cytometry FAQs
Cell-based Assays for Bioprocessing
Cell-based Assays for Gene Therapy Development
Cellometer Applications
Modern Virology Assays
Sub Section
Neutralizing Antibody Screening
AAV Vector Design
AAV Vector Transduction Efficiencies
FDA Approval for Gene Therapy
Neutralizing Antibody Screening
Topic
High-throughput Neutralization Assay of AAV-GFP Vectors Using Neutralizing Antibodies
High-throughput Neutralization Assay of AAV-GFP Vectors Using Neutralizing Antibodies
High-throughput Neutralization Assay of AAV-GFP Vectors Using Sera

In this experiment, the Celigo™ image cytometer Celigo Image Cytometer Celigo Image Cytometer  simultaneously imaged and quantified GFP expression after target cells were treated with different concentrations of nAbs.

  1. The target cells were seeded in a 96-well plate and allowed to adhere overnight
  2. Cells were transduced with AAV-A vector to low Multiplicity of Infection (MOI)
  3. Cells were pre-incubated overnight with different dilutions of nAbs and sera at 1X and 5X dilutions
  4. The Celigo was used to image and analyze the cells in brightfield and GFP fluorescence to determine transduction efficiencies

Antibody samples exerted dose-dependent neutralization effects on transduction efficiencies

The Celigo was able to directly measure the GFP+ cell percentages in the presence or absence of different concentrations of nAbs. The GFP fluorescent images and analysis results are shown in Figure 1 and Figure 2 respectively. From the GFP images, the Celigo automatically segments individual cells, allowing rapid quantification of the GFP+ percentage of total cells when compared to brightfield. 

  • The GFP fluorescent images clearly showed that 1X diluted nAb samples dramatically reduced GFP+ percentages (<1%)4
  • The graph confirms that the percentage of GFP-expressing cells was slightly higher for the 5X dilution (~18% of cells)
  • GFP+ percentages were comparable between the nAb and sera at both 1X and 5X dilutions
high throughput neutralization assay of aav gfp vectors using neutralizing antibodies

Figure 1. GFP fluorescent images for nAb treatment at 1X and 5X dilutions.

percentage of target cells treated with nab and sera

Figure 2. GFP+ percentage of target cells treated with nAb and sera at 1X and 5X dilutions demonstrating close-dependent transduction efficiencies

You may also be interested in these products

Cellaca-PLX-with-reagents
Cellaca PLX High-throughput Image Cytometer
Part number: PLX-SYS1
View details
The Celigo image cytometer facing left
Celigo Image Cytometer
Part number: 200-BFFL-5C
View details
ViaStain™ AOPI Staining Solution
ViaStain AOPI Staining Solution
Part number: CS2-0106-5ML, CS2-0106-25ML
View details
Ergonomic high-throughput counting plates (12 x 2)
Ergonomic high-throughput cell counting plates, 12 x 2 orientation
Part number: CHM24-A100-098, CHM24-A100-099, CHM24-A100-100
View details
Ergonomic high-throughput counting plates (8 x 3)
Ergonomic high-throughput cell counting plates, 8 x 3 orientation
Part number: CHM24-B100-098, CHM24-B100-099, CHM24-B100-100
View details
of 5

For research use only. Not for use in diagnostic procedures.

ON THIS PAGE
Revvity Logo

©2026 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.