Skip to main content
Revvity logo
Contact us
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • 細胞分析
  • Cellular Imaging & Analysis
  • Cellular Imaging Reagents
  • PhenoVue Antibody Internalization Kits and Reagents
  • PhenoVue Fluor 515 pH-sensitive Fab anti-human IgG, 2 x 96-wells

PhenoVue Fluor 515 pH-sensitive Fab anti-human IgG, 2 x 96-wells

PhenoVue Fluor 515 pH-sensitive Fab anti-human IgG
PhenoVue Fluor 515 pH-sensitive Fab anti-human IgG, 2 x 96-wells
PhenoVue Fluor 515 pH-sensitive Fab anti-human IgG
PhenoVue Fluor 515 pH-sensitive Fab Anti-human IgG provides robust detection of Enfortumab and Trastuzumab internalization across Nectin-4- and HER2-positive cell models, with low IgG1 control background.

PhenoVue™ Fluor 515 pH-sensitive Fab anti-human IgG is a fluorescent probe engineered for no-wash, live-cell monitoring of antibody and ADC internalization. Its pH-sensitive design helps keep fluorescence low at neutral extracellular pH and activates a photostable green fluorescent signal as the antibody–receptor complex traffics into acidic intracellular compartments, supporting real-time, kinetic profiling of deep internalization events with minimal background.

View product information

PhenoVue™ Fluor 515 pH-sensitive Fab anti-human IgG is a fluorescent probe engineered for no-wash, live-cell monitoring of antibody and ADC internalization. Its pH-sensitive design helps keep fluorescence low at neutral extracellular pH and activates a photostable green fluorescent signal as the antibody–receptor complex traffics into acidic intracellular compartments, supporting real-time, kinetic profiling of deep internalization events with minimal background.

View product information
Product variant
Add to compare Add to compare
削除
Assay Points: 2 x 96ウェルマイクロプレート
Part #:
2HFAB515PH1
For research use only. Not for use in therapeutic or diagnostic procedures.
Request more information
PhenoVue Fluor 515 pH-sensitive Fab anti-human IgG
PhenoVue Fluor 515 pH-sensitive Fab anti-human IgG, 2 x 96-wells
PhenoVue Fluor 515 pH-sensitive Fab anti-human IgG
PhenoVue Fluor 515 pH-sensitive Fab Anti-human IgG provides robust detection of Enfortumab and Trastuzumab internalization across Nectin-4- and HER2-positive cell models, with low IgG1 control background.

Loading...

Quick links
  • Product information
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Get help

Product information

  • Overview
  • Specifications
  • Spectra viewer

Overview

PhenoVue Fluor 515 pH-sensitive Fab anti-human IgG is a fluorescent reagent for real-time, no-wash live-cell imaging of antibody and ADC internalization and intracellular trafficking, supporting immuno-oncology research and ADC development.

This Fab fragment binds human IgG antibodies (IgG1–4). Its pH-sensitive fluorophore remains dim at neutral extracellular pH and produces a bright, photostable green fluorescent signal as antibody–receptor complexes traffic into acidic endosomal and lysosomal compartments. This selective activation offers kinetic profiling of internalization with minimal extracellular background.

Key features:

  • No-wash protocol: Helps simplify workflows and supports continuous live-cell monitoring.
  • Improved photostability: Supports kinetic imaging over extended periods of up to 72 hours.
  • FITC-compatible detection: Excitation at 515 nm and emission at 532 nm.
  • Broad isotype coverage: Recognizes human IgG1, IgG2, IgG3, and IgG4.
  • Evaluated across multiple cell models: Supports antibody and ADC internalization studies, including models using trastuzumab and enfortumab-based ADCs.

Compatible with PhenoPlate™ imaging microplates and Revvity high-content imaging systems.

Specifications

Form
Lyophilized
Molecular Weight
50 kDa
Application
High Content Imaging
Microscopy
Assay Points
2 x 96-well microplates
Brand
PhenoVue™
Detection Modality
Fluorescence
Format
Fab fragment
Host Species
Goat
Sample Concentration
18 µM (0.9 mg/mL) after reconstitution with 100µL H20
Sample Type
Live cells only
Shipping Conditions
Shipped Ambient
Specificity
Human IgG, Fc region
Storage Conditions
2-8°C. Protect from light
Target Species
Human
Type
Individual reagent

Spectra viewer

Resources

Are you looking for resources, click on the resource type to explore further.

  • - Any -
  • Flyer:-:1
  • Product Info:-:1
1-2 of 2 Resources
Product Info Icon
Product Info
PhenoVue Fluor 515 pH-sensitive Fab anti-human IgG antibody product information sheet

Monitor antibody & ADC internalization in live cells with PhenoVueTM Fluor 515 pH-sensitive Fab anti-human IgG antibody. No-wash...

Learn more
Flyer Icon
Flyer
PhenoVue reagents and PhenoPlate microplates for high-content imaging

Discover PhenoVue reagents and PhenoPlate microplates for multiplex imaging workflows, from live-cell to fixed-endpoint analysis.

Learn more

Loading...

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Revvity Logo

©2026 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.

Scroll Icon