Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • 細胞分析
  • Cellular Imaging & Analysis
  • Cellular Imaging Reagents
  • PhenoVue 蛍光試薬&キット​
  • PhenoVue Cal-590 AM, Calcium Indicator

PhenoVue Cal-590 AM, Calcium Indicator

PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)
PhenoVue Cal-590 AM, Calcium Indicator
PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)
PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)
PhenoVue Cal-590 AM, Calcium Indicator
PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)
PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)

PhenoVue™ Cal-590 AM is a cell permeable fluorescent Ca2+ indicator and is part of Revvity’s portfolio of cellular imaging reagents. PhenoVue Cal-590 AM Ca2+ indicator exhibits orange fluorescence and is validated for use in imaging microscopy and high-content screening applications. It exhibits a maximum excitation wavelength at 574 nm and a maximum emission wavelength of 588 nm.

View our extensive validation data in the Product Information Sheet within the Resources tab below.

View product information
Feature Specification
Cell Function Indicator Calcium indicator
Color Orange
Filter Cy3/TRITC

PhenoVue™ Cal-590 AM is a cell permeable fluorescent Ca2+ indicator and is part of Revvity’s portfolio of cellular imaging reagents. PhenoVue Cal-590 AM Ca2+ indicator exhibits orange fluorescence and is validated for use in imaging microscopy and high-content screening applications. It exhibits a maximum excitation wavelength at 574 nm and a maximum emission wavelength of 588 nm.

View our extensive validation data in the Product Information Sheet within the Resources tab below.

View product information
Product variant
Quantity: 10 x 50 µg (10 x 40 nmoles)
Part #:
CP125901
For research use only. Not for use in diagnostic procedures.
Request more information
PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)
PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)
PhenoVue Cal-590 AM, Calcium Indicator
PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)
PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)
PhenoVue Cal-590 AM, Calcium Indicator
PhenoVue Cal-590 AM, Calcium Indicator
PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)
PhenoVue Cal-590 AM, Calcium Indicator
CHO-K1 cells stained with PhenoVue Cal-590 AM (with and without ATP)
Quick links
  • Product information
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Recently viewed
  • Get help

Product information

  • Overview
  • Specifications
  • Spectra viewer

Overview

Calcium ions are important signaling molecules mediating a broad spectrum of intracellular, intercellular as well as extracellular functions. Ca2+ plays critical physiological functions such as muscle contraction, neuronal excitability, cell migration and cell growth. Intracellular Ca2+ is stored in the endoplasmic reticulum, sarcoplasmic reticulum, and the mitochondria. Upon cell surface receptors stimulation like GPCRs, calcium is released from these internal stores and its intracellular concentration increases from 100 nM to approximately 1 μM.

Intracellular Ca2+ responses have been widely investigated with fluorescent calcium probes which fluorescence signal increases upon Ca2+ binding.

The first-generation of fluorescent calcium indicators, including Fura-2, Fluo-3 and Rhod-2, were developed, followed by a second-generation, such as Fluo-4, with improved properties especially brightness and signal-to-noise ratio. However, the presence of anion transporters expressed at the cell surface may impair the intracellular retention of the fluorescent calcium indicators which are cleared out from cells. Inhibitors of these transporters, such as Probenecid, are commonly used but suffer from limitations such as cytotoxicity, off-targets, or inconsistent calcium flux kinetics. Such limitations can be overcome with third generation of fluorescent calcium indicators including Cal-520, Cal-590 and their corresponding Cal-520, Cal-590 Bright versions which do not require probenecid.

PhenoVue Fluorescent Calcium Indicators, encompassing Fura-2 AM, Fluo-4 AM, Cal-520 AM, Cal-590 AM, Cal-520 AM Bright and Cal-590 AM Bright, enable a myriad of applications as well as multiplexing capability to unravel intracellular calcium mediated functions.

PhenoVue Cal-590 AM is a cell permeable Ca2+ indicator which is metabolized by intracellular esterase and results in a negatively charged fluorescent dye. Consequently, PhenoVue Cal-590 AM exhibits higher sensitivity, significant improved signal-to-noise ratio, reduced leakage and higher intracellular retention compared to other calcium indicators such as Fura-2 AM and Fluo-4 AM.

Recommended working concentration: 5 µM

Equivalent number of microplates:

  • 3-10 x 96-well microplates
  • 3-10 x 384-well microplates
  • 4-16 x 1536-well microplates

Specifications

Color
Orange
Form
Solid
Maximum Emission Wavelength (Emmax)
588 nm
Maximum Excitation Wavelength (Exmax)
574 nm
Application
High Content Imaging
Microscopy
Brand
PhenoVue™
Cell Function Indicator
Calcium indicator
Detection Modality
Fluorescence
Filter
Cy3/TRITC
Quantity
10 x 50 µg (10 x 40 nmoles)
Sample Type
Live samples only
Shipping Conditions
Shipped in Dry Ice
Storage Conditions
-16 °C or below, protected from light
Type
Individual reagent

Spectra viewer

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Brochure:-:1
  • eBook:-:1
  • Flyer:-:2
1-2 of 2 Resources
Flyer Icon
Flyer
PhenoVue Cellular Imaging Reagents Flyer

This flyer describes Revvity's PhenoVue cellular imaging reagents.

Learn more
Flyer Icon
Flyer
PhenoVue reagents & imaging microplates product list

PhenoVue reagents & imaging microplates product list

Learn more

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.