Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • 細胞分析
  • Cell Lines & Stem Cells
  • Frozen cells
  • AequoZen Human Melatonin MT2 Cell Line

AequoZen Human Melatonin MT2 Cell Line

GPCR Receptor Cells and Membranes
AequoZen Human Melatonin MT2 Cell Line
GPCR Receptor Cells and Membranes
GPCR Receptor Cells and Membranes
GPCR Receptor Cells and Membranes

AequoZen™ Human Melatonin MT2 Cells are frozen, ready-to-use cells co-expressing aequorin and the human recombinant Human Melatonin MT2 receptor, in CHO-K1 host cells. The addition of aequorin provides a way to measure changes in intracellular calcium levels. This specialized cell line is specifically designed and manufactured for use in drug discovery and development, particularly for high-throughput screening assays.

View product information
Feature Specification
Application 創薬・開発
G-Alpha Natural Receptor Gi/Go
Validation 結合
カルシウム蛍光

AequoZen™ Human Melatonin MT2 Cells are frozen, ready-to-use cells co-expressing aequorin and the human recombinant Human Melatonin MT2 receptor, in CHO-K1 host cells. The addition of aequorin provides a way to measure changes in intracellular calcium levels. This specialized cell line is specifically designed and manufactured for use in drug discovery and development, particularly for high-throughput screening assays.

View product information
Product variant
Unit Size: 10 million cells
Part #:
ES-621-AF
For research use only. Not for use in diagnostic procedures. This product contains living cells.
Request more information
GPCR Receptor Cells and Membranes
AequoZen Human Melatonin MT2 Cell Line
GPCR Receptor Cells and Membranes
GPCR Receptor Cells and Membranes
AequoZen Human Melatonin MT2 Cell Line
GPCR Receptor Cells and Membranes
Quick links
  • Product information
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Recently viewed
  • Get help

Product information

  • Overview
  • Specifications

Overview

Frozen Cells validated for calcium testing: Melatonin MT2 receptor, human recombinant, in CHO-K1 host cell. We provide one vial of frozen cells (10 million cells/vial). You are authorized to utilize these frozen cell preparations one time only. Any attempt to transfer, re-use, or propagate these cells is expressly unauthorized and a violation of the product terms and conditions of sale.

Features:

  • Pre-validated batches of ready-to-use cells for calcium testing
  • Optimized to alleviate biological variability
  • Step-by-Step protocols for culture-free functional testing on our validated cells
  • Affordable access to small aliquots of cells (minimum size: 10 million cells/vial)
  • Ready-to-use cells for Profiling, Pharmacology or Screening applications
  • Up-scaling and customized developments

The AequoScreen technology is a generic GPCR technology which can be used with Gs, Gi and Gq coupled GPCRs and calcium coupled ion channels. Following receptor stimulation, increases in intracellular calcium enable measurement of the resulting flash luminescence signal.

The frozen cells approach to functional testing consists in the dissociation of cell culture from testing. That means that we will culture the cells and freeze them with an optimized protocol to stop all replication. These cells are then stored in liquid nitrogen or simply in a -80°C freezer, thawed and used directly in a functional, cellular GPCR test with previously validated performance.

Specifications

Application
Drug Discovery & Development
Brand
AequoZen
G-Alpha Natural Receptor
Gi/Go
Host Cell Line
CHO-K1
Host Species
Human
One Unit Contains
1 M cells/vial
Receptor
Melatonin
Second Messenger Release
Calcium flux
Shipping Conditions
Shipped in Dry Ice
Target Class
GPCR
Unit Size
10 million cells
Validation
Binding
Calcium Fluorescence

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Brochure:-:1
1-1 of 1 Resources
Brochure Icon
Brochure
Radioligand selection guide

Discover a comprehensive collection of GPCR cell lines, membrane preparations, and complementary radioligands designed to drive...

Learn more

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.