Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • タンパク質解析
  • マイクロ流体によるタンパク質特性評価
  • High Resolution LabChip GXII, Touch HT

High Resolution LabChip GXII, Touch HT

LabChip Protein Microfluidics Chip
High Resolution LabChip GXII, Touch HT
LabChip Protein Microfluidics Chip
LabChip Protein Microfluidics Chip
High Resolution LabChip GXII, Touch HT
LabChip Protein Microfluidics Chip

The High Resolution LabChip® is designed to be compatible with the Glycan Screening Assay and Low Molecular Weight Protein Assay on the LabChip® GXII microfluidic capillary electrophoresis (CE-SDS) platform. This chip is available in a single pack.

View product information
Product variants
Application: Protein Analysis
Instrument Compatibility
LabChip GXII Touch HT
Part #:
760524
Application: Protein Analysis
Instrument Compatibility
LabChip GXII Touch 24
Part #:
CLS138951
For research use only. Not for use in diagnostic procedures.
Request more information
Feature Specification
Linear Concentration Range LMW Protein 30 - 2000 ng/µL (BLG, CAII in PBS), GLycanb 1.25 - 7.5mg/mL,
Percent Purity Reproducibility LMW Protein 30% CV ≤ 80 kDa., HT Glycan: CV < 10% for a peak ≥ 2.5% of total glycans, HT Glycan Extended Range: CV < 10% for a peak ≥ 2.5% of total glycans and at a conc. 2.5 ng/L CV < 25% for a peak ≥ 2.5% of total glycans at conc. 1.0 - 2.5 ng/µL
Sample Type Glycan
Protein
Size Range LMW Protein Express 5 - 80 kDa, HT Glycan: neutral glycans found on mAbs, some charged glycans may run outside of our usable range HT Glycan Extended Range: neutral and charged glycans found on mAbs
Sizing Precision RSD (CV) LMW Protein ± 20% up to 80 kDa ± 10% (CAII, BLG), Glycan CV < 2.5%
Sizing Resolution LMW Protein ± 10% 14 - 80 kDa ± 20% < 14 kDa
Unit Size 1 chip
Feature Specification
Linear Concentration Range LMW Protein 30 - 2000 ng/µL (BLG, CAII in PBS), GLycanb 1.25 - 7.5mg/mL,
Percent Purity Reproducibility LMW Protein 30% CV ≤ 80 kDa., HT Glycan: CV < 10% for a peak ≥ 2.5% of total glycans, HT Glycan Extended Range: CV < 10% for a peak ≥ 2.5% of total glycans and at a conc. 2.5 ng/L CV < 25% for a peak ≥ 2.5% of total glycans at conc. 1.0 - 2.5 ng/µL
Sample Type Glycan
Protein
Size Range LMW Protein Express 5 - 80 kDa, HT Glycan: neutral glycans found on mAbs, some charged glycans may run outside of our usable range HT Glycan Extended Range: neutral and charged glycans found on mAbs
Sizing Precision RSD (CV) LMW Protein ± 20% up to 80 kDa ± 10% (CAII, BLG), Glycan CV < 2.5%
Sizing Resolution LMW Protein ± 10% 14 - 80 kDa ± 20% < 14 kDa
Unit Size 1 chip
Request more information
Quick links
  • Variants
  • Product information
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Recently viewed
  • Customers also bought
  • Get help

Product information

  • Overview
  • Specifications

Overview

The High Resolution LabChip® is designed to be compatible with the Glycan Screening Assay and Low Molecular Weight Protein Assay on the LabChip GXII Touch protein characterization system.

This chip works with the following Reagent kits (sold separately):

  • Glycan Screening Reagent Kit (P/N 760525)
  • Low Molecular Weight Protein Reagent Kit (P/N 760573)

Specifications

Application
Protein Analysis
Automation Compatible
Yes
Instrument Compatibility
LabChip GXII Touch HT
Linear Concentration Range
LMW Protein 30 - 2000 ng/µL (BLG, CAII in PBS), GLycanb 1.25 - 7.5mg/mL,
Percent Purity Reproducibility
LMW Protein 30% CV ≤ 80 kDa., HT Glycan: CV < 10% for a peak ≥ 2.5% of total glycans, HT Glycan Extended Range: CV < 10% for a peak ≥ 2.5% of total glycans and at a conc. 2.5 ng/L CV < 25% for a peak ≥ 2.5% of total glycans at conc. 1.0 - 2.5 ng/µL
Sample Type
Glycan
Protein
Sample Volume
LMW Protein 2 µL, Glycan 8µL
Size Range
LMW Protein Express 5 - 80 kDa, HT Glycan: neutral glycans found on mAbs, some charged glycans may run outside of our usable range HT Glycan Extended Range: neutral and charged glycans found on mAbs
Sizing Precision RSD (CV)
LMW Protein ± 20% up to 80 kDa ± 10% (CAII, BLG), Glycan CV < 2.5%
Shipping Conditions
Shipped in Blue Ice Soft
Sizing Resolution
LMW Protein ± 10% 14 - 80 kDa ± 20% < 14 kDa
Technology
Microfluidic Electrophoresis
Unit Size
1 chip

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Product Note:-:1
1-1 of 1 Resources
Product Note Icon
Product Note
Automated characterization of proteins and nucleic acids

Read the LabChip® GXII Touch™ protein characterization system product note to learn about an automated alternative to traditional...

Learn more

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.