View All
| Feature | Specification |
|---|---|
| Application | タンパク質定量 |
| Dynamic Range | 34 - 100,000 pg/mL |
| Limit of Detection | 34 pg/mL |
| Limit of Quantification | 121 pg/mL |
| Sample Volume | 10 µL |
Formats:
Features:
AlphaLISA technology allows the detection of molecules of interest in buffer, cell culture media, serum and plasma in a highly sensitive, quantitative, reproducible and user-friendly mode. In an AlphaLISA assay, a Biotinylated Anti-Analyte Antibody binds to the Streptavidin-coated Alpha Donor beads, while another Anti-Analyte Antibody is conjugated to AlphaLISA Acceptor beads. In the presence of the analyte, the beads come into close proximity. The excitation of the Donor beads provokes the release of singlet oxygen molecules that triggers a cascade of energy transfer in the Acceptor beads, resulting in a sharp peak of light emission at 615 nm.
Cytotoxic T-lymphocyte-associated protein 4 (CTLA4 or CTLA-4) is known as CD152 (cluster of differentiation 152). CTLA-4, as a protein receptor, is a critical biomarker for immune checkpoints. It is constitutively expressed in regulatory T cells (such as suppressor T cells) and the expression is upregulated in conventional T cells after activation. CTLA-4 acts as an "off" switch when bound to CD80 or CD86 on the surface of antigen-presenting cells. Thus, CTLA-4 is associated with numerous disease conditions such as insulin-dependent diabetes mellitus, systemic lupus erythematosus and other autoimmune diseases and cancers. Soluble CTLA-4 levels in biofluids have become a biomarker for determining the health status in patients. This kit is designed to detect and quantify the levels of CTLA-4 in cell culture supernatant, serum, and cell lysates.
The AlphaLISA assay is based on an AlphaLISA sandwich immunoassay involving a biotinylated anti-analyte antibody bound to Streptavidin-coated AlphaLISA Donor beads and an anti-analyte antibody conjugated to AlphaLISA Acceptor beads. Both antibodies are directed against the analyte of interest. In the presence of the target, both antibodies bind to analyte and the beads come into proximity. The excitation of the Donor beads provokes the release of singlet oxygen molecules that triggers a cascade of energy transfer within the Acceptor beads, resulting in emission with λmax at 615 nm. The intensity of the signal is directly proportional to the concentration of analyte present in the sample.
The AlphaLISA assay can be run in a 96- or 384-well detection plate (50 µL final). As described here, samples or standards are dispensed directly into the assay plate for the detection of the analyte of interest by AlphaLISA reagents. No washing steps are needed. The protocol can be further miniaturized or upscaled by simply resizing each addition volume proportionally.
| Application |
Protein Quantification
|
|---|---|
| Automation Compatible |
Yes
|
| Brand |
AlphaLISA
|
| Detection Modality |
Alpha
|
| Dynamic Range |
34 - 100,000 pg/mL
|
| Limit of Detection |
34 pg/mL
|
| Limit of Quantification |
121 pg/mL
|
| Product Group |
Kit
|
| Sample Volume |
10 µL
|
| Shipping Conditions |
Shipped in Blue Ice
|
| Target |
CTLA4
|
| Target Class |
Biomarkers
|
| Target Species |
Human
|
| Technology |
Alpha
|
| Therapeutic Area |
Oncology
|
| Unit Size |
100 assay points
|
Are you looking for resources, click on the resource type to explore further.
Membrane proteins, which are key in cellular signaling and often serve as disease biomarkers, are a significant focus in research...