Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • 研究・開発
  • タンパク質解析
  • イムノアッセイ
  • Alphaアッセイ
  • AlphaLISA SureFire Ultra Human and Mouse Total AKT2 Detection Kit, 10,000 Assay Points

AlphaLISA SureFire Ultra Human and Mouse Total AKT2 Detection Kit, 10,000 Assay Points

AlphaLISA Surefire Ultra Total Protein
AlphaLISA SureFire Ultra Human and Mouse Total AKT2 Detection Kit, 10,000 Assay Points
AlphaLISA Surefire Ultra Total Protein
AlphaLISA Surefire Ultra Total Protein
AlphaLISA Surefire Ultra Total Protein

The AlphaLISA™ SureFire® Ultra™ Human and Mouse Total AKT2 assay is a sandwich immunoassay for quantitative detection of total AKT2 in cellular lysates using Alpha Technology.

View product information
Feature Specification
Application 細胞シグナル伝達
Protocol Time 2h at RT
Sample Volume 10 µL

The AlphaLISA™ SureFire® Ultra™ Human and Mouse Total AKT2 assay is a sandwich immunoassay for quantitative detection of total AKT2 in cellular lysates using Alpha Technology.

View product information
Product variants
Unit Size: 100 assay points
Part #:
ALSU-TAKT2-A-HV
Unit Size: 500 assay points
Part #:
ALSU-TAKT2-A500
Unit Size: 10,000 assay points
Part #:
ALSU-TAKT2-A10K
Unit Size: 50,000 assay points
Part #:
ALSU-TAKT2-A50K
For research use only. Not for use in diagnostic procedures. All products to be used in accordance with applicable laws and regulations including without limitation, consumption and disposal requirements under European REACH regulations (EC 1907/2006).
Request more information
AlphaLISA Surefire Ultra Total Protein
AlphaLISA SureFire Ultra Human and Mouse Total AKT2 Detection Kit, 10,000 Assay Points
AlphaLISA Surefire Ultra Total Protein
AlphaLISA Surefire Ultra Total Protein
AlphaLISA SureFire Ultra Human and Mouse Total AKT2 Detection Kit, 10,000 Assay Points
AlphaLISA Surefire Ultra Total Protein
Quick links
  • Variants
  • Product information
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Get help

Product information

  • Overview
  • How it works
  • Assay validation
  • Assay specificity/selectivity
  • Assay versatility
  • Specifications

Overview

AKT2 is a serine/threonine protein kinase and a key member of the PI3K/AKT signaling pathway, playing critical roles in glucose metabolism, insulin sensitivity, and cellular survival. AKT2 is activated by phosphorylation at Thr308 and Ser473 downstream of PI3K, promoting glucose uptake, glycogen synthesis, and lipogenesis while inhibiting gluconeogenesis. It is particularly important in muscle and adipose tissue for maintaining glucose homeostasis. Mutations or altered expression of AKT2 are associated with type 2 diabetes, metabolic syndrome, and various cancers including breast, ovarian, and pancreatic carcinomas. In oncology, AKT2 promotes tumor cell survival, proliferation, and metastasis while conferring resistance to apoptosis. Therapeutic targeting of AKT2 through selective inhibitors represents a promising strategy for both metabolic disorders and cancer treatment.

The AlphaLISA SureFire Ultra Human and Mouse Total AKT2 is a sandwich immunoassay for the quantitative detection of total AKT2 in cellular lysates, using Alpha Technology.

Formats:

  • The HV (high volume) kit contains reagents to run 100 wells in 96-well format, using a 60 μL reaction volume.
  • The 500-point kit contains enough reagents to run 500 wells in 384-well format, using a 20 μL reaction volume.
  • The 10,000-point kit contains enough reagents to run 10,000 wells in 384-well format, using a 20 μL reaction volume.
  • The 50,000-point kit contains enough reagents to run 50,000 wells in 384-well format, using a 20 μL reaction volume.

AlphaLISA SureFire Ultra kits are compatible with:

  • Cell and tissue lysates
  • Antibody modulators
  • Biotherapeutic antibodies

AlphaLISA SureFire Ultra kits can be used for:

  • Cellular kinase assays
  • Receptor activation studies
  • High-throughput screening for preclinical studies

How it works

Total-AlphaLISA SureFire Ultra assay principle

The Total-AlphaLISA SureFire Ultra assay measures the expression level of a protein target in a cell lysate.

The Total-AlphaLISA SureFire Ultra assay uses two antibodies which recognize two different distal epitopes on the targeted protein. AlphaLISA assays require two bead types: Acceptor and Donor beads. Acceptor beads are coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody, labeled with a CaptSure tag. Donor beads are coated with streptavidin to capture one of the detection antibodies, which is biotinylated. In the presence of targeted protein, the two antibodies bring the Donor and Acceptor beads in close proximity whereby the singlet oxygen transfers energy to excite the Acceptor bead, allowing the generation of a luminescent Alpha signal. The amount of light emission is directly proportional to the quantity of protein present in the sample.

assay-principle-Total-AlphaLISA-Surefire-Ultra.jpg

 

Total-AlphaLISA SureFire Ultra two-plate assay protocol

The two-plate protocol involves culturing and treating the cells in a 96-well plate before lysis, then transferring lysates into a 384-well OptiPlate™ plate before the addition of Total-AlphaLISA SureFire Ultra detection reagents. This protocol permits the cells viability and confluence to be monitored. In addition, lysates from a single well can be used to measure multiple targets.

2 plates assay protocol AlphaLISA Surefire Ultra Total assay

Total-AlphaLISA SureFire Ultra one-plate assay protocol

Detection of Total target protein with AlphaLISA SureFire Ultra reagents can be performed in a single plate used for culturing, treatment, and lysis. No washing steps are required. This HTS designed protocol allows for miniaturization while maintaining AlphaLISA SureFire Ultra quality.

1-plate-assay-protocol-AlphaLISA-Surefire-Ultra-Total-assay

Assay validation

Validation of AKT2 Total in insulin treated cells

MCF7 and NIH/3T3 cells were seeded in a 96-well plate (40,000 cells/well) in complete medium and incubated overnight at 37°C, 5% CO2. The cells were starved for 2 hours and then treated with increasing concentrations of insulin for 30 minutes.

After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). AKT2 Phospho (Ser474) and Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, insulin triggered a dose-dependent increase in the levels of AKT2 Phospho (Ser474), while total levels remained unchanged.

Validation of AKT2 Total in insulin treated cells
Validation of AKT2 Total in insulin treated cells

Validation of AKT2 Total in IGF-1 treated cells

HeLa cells were seeded in a 96-well plate (40,000 cells/well) in complete medium and incubated overnight at 37°C, 5% CO2. The cells were starved for 2 hours and then treated with increasing concentrations of IGF-1 for 15 minutes.

After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). AKT2 Phospho (Ser474) and Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, IGF-1 triggered a dose-dependent increase in the levels of AKT2 Phospho (Ser474), while Total levels remained unchanged.

HeLa cells treated with IGF 1

 

Validation of AKT2 Total in HEK293 cells

HEK293 cells were seeded in a 96-well plate (40,000 cells/well) in complete medium and incubated overnight at 37°C, 5% CO2. The cells were treated for 24 hours with increasing concentrations of Luminespib for 24 hours.

After treatment, the cells were lysed with 200 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). AKT2 Phospho (Ser474) and Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 2,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, Luminespib triggered a dose-dependent decrease in the levels of AKT2 Phospho (Ser474), while Total levels remained unchanged.

HEK293 cells treated with Luminespib

HEK293 cells were seeded in a 96-well plate (40,000 cells/well) in complete medium and incubated overnight at 37°C, 5% CO2. The cells were treated for 2 hours with increasing concentrations of Wortmannin for 2 hours.

After treatment, the cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). AKT2 Phospho (Ser474) and Total levels were evaluated using respective AlphaLISA SureFire Ultra assays. For the detection step, 10 µL of cell lysate (approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, Wortmannin triggered a dose-dependent decrease in the levels of AKT2 Phospho (Ser474), while total levels did not change significantly.

HEK293 cells treated with Wortmannin

Specific degradation of AKT2 using MS170 PROTAC

PC3 cells were seeded in a 96-well plate (40,000 cells/well) in complete medium and incubated overnight at 37°C, 5% CO2. The cells were treated with increasing concentrations of MS170 PROTAC for 24 hours.

After treatment, the cells were washed with HBSS and lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm). AKT2 and Cofilin Total levels were evaluated using AlphaLISA SureFire Ultra. For the detection step, 10 µL of cell lysate (approximately 4,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at RT. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

As expected, MS170 PROTAC induced a specific dose-dependent decrease in the levels of AKT2.

PC3 cells treated with MS170 PROTAC

Assay specificity/selectivity

Specificity of AKT2 Total assay

Specificity of the AKT2 Total assay for AKT2 protein was assessed by assaying active recombinant AKT1, AKT2 and AKT3 proteins.

Dilutions of AKT1 (Abcam, ab62279), AKT2 (Abcam, ab60324) and AKT3 (Abcam, ab60324) proteins were prepared in Lysis Buffer at the indicated concentrations. AKT2 Total signal was evaluated using the AlphaLISA SureFire Ultra assay. For the detection step, 10 µL of protein was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at room temperature. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

Alpha signal was only detected with AKT2 recombinant protein, while no cross-reactivity was observed with AKT1 and AKT3 proteins. These results demonstrate the specificity of the AKT2 Total assay as these three proteins shares approximately 80% sequence identity.

AKT2 Total assay specificity

Assay versatility

AKT2 expression in various cell lines

Adherent cell lines were seeded in a 96-well plate (40,000 cells/well) and incubated overnight at 37°C, 5% CO2. Cells were lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm).

Suspension cell lines were seeded in a 96-well plate (400,000 cells/well) in HBSS + 0.1% BSA and then lysed with 100 µL of Lysis Buffer for 10 minutes at RT with shaking (350 rpm).

AKT2 Total levels were evaluated by AlphaLISA SureFire Ultra. For the detection step, 10 µL of cell lysate (approximately 4,000 adherent cells or 40,000 suspension cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor Mix and incubated for 1 hour at RT. Finally, 5 µL of Donor Mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.

AKT2 expression in various cell lines

Specifications

Application
Cell Signaling
Automation Compatible
Yes
Brand
AlphaLISA SureFire Ultra
Detection Modality
Alpha
Product Group
Kit
Protocol Time
2h at RT
Sample Volume
10 µL
Shipping Conditions
Shipped in Blue Ice
Target
AKT2
Target Class
Phosphoproteins
Target Species
Human
Mouse
Technology
Alpha
Therapeutic Area
Metabolic
Oncology
Unit Size
10,000 assay points

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Brochure:-:2
1-2 of 2 Resources
Brochure Icon
Brochure
Alpha assays and reagents catalog

Alpha technolgy enables the rapid and straightforward mesaure of virtually any target. This includes enzymes, receptor-ligand...

Learn more
Brochure Icon
Brochure
Species compatibility for HTRF, AlphaLISA SureFire Ultra and Alpha SureFire Ultra Multiplex assays

This document includes detailed tables listing HTRF™, AlphaLISA™ SureFire® Ultra™, and Alpha SureFire® Ultra™ Multiplex assays...

Learn more

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2026 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.