Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Products
  • プラットフォームと自動化
  • 検出システムソリューション
  • 放射性化学物質
  • Iodo-(-)-Cyanopindolol, [125I], 500µCi (18.5MBq)

Iodo-(-)-Cyanopindolol, [125I], 500µCi (18.5MBq)

NENSure radiochemical vial and container
Iodo-(-)-Cyanopindolol, [125I], 500µCi (18.5MBq)
NENSure radiochemical vial and container
NENSure™ radiochemical vial and container
NENSure radiochemical vial and container

Iodo-(-)-cyanopindolol, labeled with 125I. Cyanopindolol acts as an antagonist at β1 adrenergic receptors and serotonin 5-HT1A receptors.

View product information
Feature Specification
Fresh Lot Days First Monday of each month
Label Position Nominally Labeled
Molecular Weight 411
Receptor Adrenoceptors

Iodo-(-)-cyanopindolol, labeled with 125I. Cyanopindolol acts as an antagonist at β1 adrenergic receptors and serotonin 5-HT1A receptors.

View product information
Product variants
Unit Size: 100 µCi
Part #:
NEX189100UC
Unit Size: 500 µCi
Part #:
NEX189500UC
For research use only. Not for use in diagnostic procedures.
Request more information
NENSure radiochemical vial and container
Iodo-(-)-Cyanopindolol, [125I], 500µCi (18.5MBq)
NENSure radiochemical vial and container
NENSure™ radiochemical vial and container
Iodo-(-)-Cyanopindolol, [125I], 500µCi (18.5MBq)
NENSure radiochemical vial and container
Quick links
  • Variants
  • Product information
  • Resources
  • SDS, COAs, manuals and more
  • Related products
  • Recently viewed
  • Get help

Product information

  • Overview
  • Specifications

Overview

500 µCi Quantities of iodo-(±)-Cyanopindolol, [125I], are available for your research.

We offer radioligands and radiolabeled biomolecules to use as tracers, for radioimmunoassays (RIAs), for autoradiographic visualization, or for performing saturation and competition radioligand binding assays to determine receptor expression levels (Bmax), dissociation constants (Kd), association and dissociation rates (kon and koff), and inhibitor constants (Ki) for a variety of receptors. We develop our radioligands to the highest specific activity possible and provide high purity resulting in low non-specific binding products. Each of our ultra-pure radiolabeled compounds is fully characterized for pharmacological action and validated in binding assays.

Radiochemicals remain the most sensitive method for probing binding biology; yielding unprecedented sensitivity gives results that technicians and scientists can trust. For over 50 years, Revvity has been a leading supplier of New England Nuclear (NEN) radiochemicals, liquid scintillation cocktails, vials and nuclear counting detection instruments.

References for NEX189:

  1. Houseknecht, K., Bauman, D., Carey, G., Mersmann, H., (1995), Effect of bovine somatotropin and food deprivation on β-adrenergic and A1 adenosine receptor binding in adipose tissue of lactating cows, Domestic Animal Endocrinology, 12 (4): 325-336.
  2. Mersmann, H., McNeel, R., Morkeberg, J., Shparber, A., Hachey, D., (1992), β-Adrenergic Receptor-Mediated Functions in Porcine Adipose Tissue Are Not Affected Differently by Saturated vs. Unsaturated Dietary Fats, The Journal of Nutrition, 122 (10): 1952–1959.

Specifications

Molecular Weight
411
Specific Activity
2200 Ci/mmol (81.4 TBq/mmol)
CAS Number
85124-14-7
Application
Drug Discovery & Development
Brand
NEN Radiochemicals
Buffer/Solvent
1 propanaol : water : phenol (~50:50:1 2)
Detection Modality
Radiometric
Fresh Lot Days
First Monday of each month
Label Position
Nominally Labeled
Molecular Formula
C16H20IN3O2
Packaging
NENSure vial
Radioisotope
125I
Receptor
Adrenoceptors
Shipping Information
Shipped on Dry Ice
Shipping Conditions
Shipped in Dry Ice
Special Ordering Information
This is a radioactive product - shipping address must have a license to receive radioactive materials.
Storage Conditions
4°C
Therapeutic Area
CNS & Neurologic
Unit Size
500 µCi

Resources

Are you looking for resources, click on the resource type to explore further.

  • - すべて -:-:- Any -
  • Flyer:-:1
  • Product Info:-:1
1-2 of 2 Resources
Product Info Icon
Product Info
Calendar: NEN® Radiochemicals Fresh Lot
Learn more
Flyer Icon
Flyer
NENSure the safest packaging for radiochemicals
Learn more

How can we help you?

We are here to answer your questions.

Contact sales I would like more product information Contact customer care Get technical support
Get Help Illustration Get Help Illustration
Scroll Icon
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.