Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Explore six key detection technologies

Six key detection technologies

Explore the strengths of six key detection technologies with the VICTOR Nivo, each tailored to deliver accurate, sensitive results across diverse research and assay needs.

Absorbance

Absorbance is a well-established and widely used microplate assay format, ideal for applications such as ELISA, protein and nucleic acid quantification, and enzyme activity measurements.

The VICTOR Nivo™ multimode plate reader provides flexible absorbance detection, offering users the option of either a filter-based detection for maximum sensitivity or spectrometer system for full-spectrum absorbance. The spectrometer-based plate reader captures ultra-fast, full-spectrum measurements from 230-1000 nm at selectable resolutions (2.0 nm, 5.0 nm, 10 nm) in under one second per well, with up to eight wavelengths measured simultaneously. This enables accurate detection across a wide range of dyes and supports analysis of samples with unknown absorbance spectra.

Alpha

Alpha is a high-performance, laser-based detection technology used with AlphaScreen™ and AlphaLISA™ kits. It enables fast, no-wash assays for complex samples across a wide range of applications.

Luminescence

Luminescence measures light from chemical or biochemical reactions without external excitation. It offers high sensitivity, low background, and is ideal for reporter gene, cytotoxicity, and proliferation assays.

Fluorescence intensity

Fluorescence intensity measures light emitted from excited fluorophores. It's a widely used and highly sensitive detection mode, ideal for precise DNA/protein quantitation, reporter-gene expression, and protein binding assays.

Fluorescence polarization

Fluorescence polarization detects binding events by measuring light emitted from fluorophores excited with polarized light. It's ideal for high-throughput screening of receptor-ligand binding, protein interactions, and immunoassays.

Time-resolved fluorescence

Time-resolved fluorescence (TRF) uses lanthanide labels to emit light over time, reducing background noise. It offers high sensitivity and dynamic range - ideal for low-concentration or limited-sample immunoassays.

The VICTOR Nivo is certified for use with HTRF™ technology.

VICTOR Nivo multimode microplate reader
line

Questions?
We're here to help.

Contact us
Revvity Logo

©2025 Revvity - All rights reserved

Revvity is a trademark of Revvity, Inc. All other trademarks are the property of their respective owners.