Skip to main content
メニュー
Revvity logo
Contact us
JP
Revvity Sites Globally

Select your location.

*e-commerce not available for this region.

australia.webp Australia
austria.webp Austria
belgium.webp Belgium
brazil.webp Brazil *
canada.webp Canada
china.webp China *
denmark.webp Denmark
finland.webp Finland
france.webp France
germany.webp Germany
hong-kong.webp Hong Kong (China) *
india.webp India *
ireland.webp Ireland
italy.webp Italy
japan.webp Japan *
luxembourg.webp Luxembourg
mexico.webp Mexico *
netherlands.webp Netherlands
norway.webp Norway
philippines.webp Philippines *
republic of korea.webp Republic of Korea *
singapore.webp Singapore *
spain.webp Spain
sweden.webp Sweden
switzerland.webp Switzerland
thailand.webp Thailand *
uk.webp United Kingdom
usa.webp United States
Breadcrumb
...
  • ホーム
  • Knowledge Base
  • RadiometricSection
  • Solid Scintillant Alternative - MeltiLex
Radiometric

Solid Scintillant Alternative - MeltiLex

Section
Liquid Scintillation Counting
Acetylation Assays Using Acetyl CoA
CAT Reporter Gene Assays
Cell and Metabolic Labeling
Chromium-51 Release Assay
DNA and RNA Labeling
Glucose Uptake Assays
In Vitro Kinase Assays
Iodine-125 Labeling of Proteins
Liquid Scintillation Counting
Phosphorus-32 Cell Labeling Assays
Phosphorylation Assays
Radiochemical Calculations
Radioimmunoassays
Radiometric Assays and Detection
Radiometric Ligand-Binding Assays
Scintillation Proximity Assays
Sulfur-35 GTP Binding Assays
Sulfur-35 Methionine Labeling
Thymidine Uptake Assays
Which Formulation Should I Choose?
Sub Section
Solid Scintillant Alternative - MeltiLex
Alpha-Beta Discrimination
Liquid Scintillation Cocktails
Quench, Counting Efficiency, and Quench Correction
Sample Preparation for LSC
Solid Scintillant Alternative - MeltiLex

Overview

MeltiLex™ is a solid scintillant alternative to liquid scintillation cocktails for Filtermat samples. MeltiLex is a unique melt-on scintillator for dry on support counting for use with Filtermat.

  • MeltiLex A – used with Filtermat A (catalog number 1450-421). GF/C filters are thin, and typically used for whole cell assays such as 3H-thymidine incorporation assays.
  • MeltiLex B – used with Filtermat B (catalog number 1450-521). GF/B filters are typically used in cell-membrane based assays, such as receptor-ligand binding assays.

The Filtermat -plus-cocktail combination provides increased tritium counting efficiency. In a thymidine uptake experiment, the relative counting efficiencies of Filtermat with MeltiLex and HARVEST Plate with cocktail are 53% and 68%, respectively. Both methods exhibited similar consistencies in count rate and therefore harvesting efficacy. Results from the two-dilution series also showed excellent correlation.